Related Experiment Video
Updated: Aug 23, 2025

An Improved Mechanical Testing Method to Assess Bone-implant Anchorage
Published on: February 10, 2014
Biomechanical analysis of stress around the tilted implants with different cantilever lengths in all-on-4 concept
Qi Wang1, Zhen-Zhen Zhang2, Shi-Zhu Bai3
1State Key Laboratory of Military Stomatology & National Clinical Research Center for Oral Diseases & Shaanxi Key Laboratory of Stomatology, Department of Pediatric Dentistry, School of Stomatology, The Fourth Military Medical University, No.145, Changle West Road, Xincheng District, Shaanxi, Xi'an, China.
Background:
Many clinical studies have reported the high success rate of the All-on-4 concept. In the present study, we aimed to compare the stress distribution with different tilted distal implants and cantilever lengths in an All-on-4 system using the two-dimensional photoelastic method and to establish the All-on-4 implant photoelastic model by computer-aided design (CAD) and rapid prototyping (RP). METHODS: The data of the human edentulous mandible were acquired by computed tomography (CT). Three human edentulous mandible All-on-4 implant models with different distally inclined implant holes were fabricated using Mimic, Geomagic Studio software, and a light solidifying fast shaping machine. Then the final photoelastic models were established through the traditional method. Each of the three models had four NobelSpeedy Replace implants between the interforaminal regions. The two posterior implants were placed 0, 15, and 45 degrees distally before the mental foramen. The four implants were splinted by wrought cobalt-chromium alloy frameworks. Each of the three photoelastic models was submitted to a 150 N vertical load at five points on the framework: the central fossa of the mandibular first molar, and 0 mm, 5 mm, 10 mm, and 15 mm of the cantilever length. The stress produced in the models was photographed with a digital camera, and the highest value of the stressed fringe pattern was recorded.
Results:
The All-on-4 implant photoelastic model established by CAD and RP was highly controllable and easy to modify. The position and inclination of implants were accurate, and the frameworks could be passively emplaced. The stress values were higher around a single tilted implant compared with the distal implant in All-on-4 with the same inclination. The 0-degree distal implant and 45-degree distal implant demonstrated the highest and lowest stress when loading at the central fossa of the mandibular first molar, respectively. With the same inclination of distal implant, the peri-implant bone stress increased as the length of cantilever increased.
Conclusion:
The method of establishing the All-on-4 implant photoelastic model by CAD and RP was highly controllable, convenient, fast, and accurate. The tilted implants splinted in the fully fixed prosthesis with reduced cantilever lengths did not increase the stress level compared with the vertical distal implants.And this illustrated that the influence of cantilever on stress distribution was greater than the influence of implant inlination.
Related Concept Videos
Stress: General Loading Conditions
The shearing force, possessing potential directionality within the plane of the section, is simplified into two component forces running parallel to the x and y axes....
Impact Loading on a Cantilever Beam
When an object is dropped onto the free end of a cantilever, its potential energy due to gravity is...
Transformation of Plane Stress
Components of Stress
Interestingly, the hidden cube faces also experience these stresses, equal and...
Shearing Stresses in a Beam: Problem Solving
Stress on an Oblique Plane

