Related Experiment Video
Updated: Aug 22, 2025

A Mini-Invasive Internal Fixation Technique for Studying Immobilization-Induced Knee Flexion Contracture in Rats
Published on: May 20, 2019
Incidence of Flexor Tendon Injuries in Complex Intra-Articular Distal Radius Fractures Fixed With Volar Rim Plate
Wei Siong Chua1, Sallehuddin Hassan2, Anizar Faizi Anoar2
1Orthopaedics and Traumatology, Hospital Kuala Lumpur, Kuala Lumpur, MYS.
The volar rim plate effectively treats complex distal radius fractures with minimal flexor tendon irritation. Most patients reported satisfactory outcomes, with low Disabilities of the Arm, Shoulder, and Hand (DASH) scores and no tendon ruptures.
Area of Science:
- Orthopedic surgery
- Traumatology
- Hand surgery
Background:
- Distal radius fractures, particularly those involving the volar rim and lunate fossa, present complex treatment challenges.
- The volar rim plate is designed for anatomical contouring and buttressing of these critical fragments.
- Minimizing soft tissue complications, such as flexor tendon irritation, is a key consideration in implant design.
Purpose of the Study:
- To evaluate the clinical outcomes of volar rim plate fixation for distal radius fractures.
- To assess the Disabilities of the Arm, Shoulder, and Hand (DASH) scores at approximately one year post-operation.
- To determine the incidence of flexor tendon irritation or rupture following volar rim plate surgery.
Main Methods:
- A prospective study included patients with AO-23B3 and AO-23C (1-3) distal radius fractures treated with volar rim plates between June 2020 and May 2021.
- Patients underwent clinical evaluation at 12 months post-surgery.
- Outcomes were assessed using the DASH score and clinical examination for signs of flexor tendon irritation or rupture.
Main Results:
- Twenty-five patients were included in the final analysis.
- The mean DASH score was 16.3, indicating a generally satisfactory functional outcome.
- Two patients (8%) experienced flexor tendon irritation, but no cases of tendon rupture were observed.
Conclusions:
- The volar rim plate is a viable option for complex intra-articular distal radius fractures.
- The study found a low incidence of flexor tendon irritation, suggesting the implant's low-profile design is beneficial.
- While outcomes were satisfactory in this series, careful monitoring for tendon irritation is warranted for potential early implant removal.
More Related Videos
Related Concept Videos
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a...
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Bones of the Upper Limb: Ulna
Muscles of the Forearm that Move the Hand and Fingers
Anterior Compartment
The anterior compartment muscles originate from the humerus. They primarily function as flexors and are also known as flexor muscles. They typically insert on the carpals, metacarpals, and phalanges. The superficial layer includes the flexor carpi...