Computed Tomography Radiation Exposure among Urinary Tract Stone Patients at Tikur Anbessa Specialized Hospital: A
Seife Teferi Dellie1, Tensae Nebiyou1, Daniel Admassie Tadesse1
1Department of Radiology, College of Health Sciences, Addis Ababa University.
Background:
National and multinational surveys indicate large variability of Computed Tomography urinary tract Stone doses. The wide use of abdominopelvic Computed Tomography in the diagnosis, raised the issue of radiation exposure. Hence, this study was conducted to assess Computed Tomography radiation exposure of urinary tract Stone Patients there by, to compare the results from established reference values and other published studies.
Methods:
A retrospective cross-sectional was done on 100 urinary tract Stone patients who have at least one computed tomography scan as part of their follow-up or for diagnosis purposes from February 1 to May 31, 2021, at Tikur Anbesa Specialized Hospital. Data were collected using a structured questionnaire format that evaluates the number of Computed Tomography they had, scan parameters, dose indicators, and socio-demographic characteristics. Finally, the collected data were analyzed using statistical software SPSS version 22.
Results:
Out of 100 patients 3.6%of our patients have radiation exposure of more than 4mSv, which is the standard for low-dose Computed Tomography. The median radiation exposure is 1.27mSv per scan. Exposure factors like tube current, tube current products, dose length product, and scan range all have similar values with an almost null interquartile range. All the scans that overpassed the low dose threshold(4mSv) were done outside Tikur Anbesa Specialized Hospital.
Conclusion:
Our study showed that Tikur Anbesa Specialized Hospital's low-dose CT protocol for patients with urinary tract Stone is well optimized as opposed to non- Tikur Anbesa Specialized Hospital.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Urinary Tract Infection III: Diagnostic Studies and Interprofessional Care
Urinary Tract Calculi I: Introduction
Urinary Tract Calculi III: Medical Management
Urinary Tract Calculi VI: Surgical Management
Imaging Studies III: Computed Tomography