Related Experiment Video
Updated: Aug 22, 2025

Qualitative Identification of Carboxylic Acids, Boronic Acids, and Amines Using Cruciform Fluorophores
Published on: August 19, 2013
Dual-Color 2D Lead-Organic Framework with Two-Fold Interlocking Structures for the Detection of Nitrofuran
Yuhang Liu1,2, Yi Zhang1, Pran Gopal Karmaker1
1College of Chemistry and Chemical Engineering, Chemical Synthesis and Pollution Control Key Laboratory of Sichuan Province, China West Normal University, Nanchong 637000, P. R. China.
Abstract:
The misuse of organic pollutants such as nitrofuran antibiotics (NFAs) and 2,6-dichloro-4-nitroaniline (DCN) has become a hot topic of global concern, and developing rapid, efficient, and accurate techniques for detecting NFAs and pesticides in water is a major challenge. Here, we designed a novel lead-based anion 2D metal-organic framework (MOF){[(CH3)2NH2]2[Pb(TCBPE)(H2O)2]} (F3) with interlocking structures, in which TCBPE stands for 1,1,2,2-tetra(4-carboxylbiphenyl)ethylene. Powder X-ray diffraction and thermogravimetric analysis revealed that F3 has excellent chemical and solvent stability. It is worth noting that F3 has a grinding discoloration effect. The solvent-protected grinding approach achieved F3B with a high quantum yield (QY = 73.77%) and blue fluorescence, while the direct grinding method produced F3Y with a high quantum yield (QY = 37.27%) and yellow-green fluorescence. Importantly, F3B can detect NFAs in water rapidly and sensitively while remaining unaffected by other antibiotics. F3Y can identify DCN in water quickly and selectively while remaining unchanged by other pesticides. F3B demonstrated high selectivity and rapid response to NFAs at a limit of detection (LOD) as low as 0.26 μM, while F3Y indicated high selectivity and responded quickly to DCN in water at an LOD as low as 0.14 μM. The method was successfully applied to detect NFAs in actual water samples of the fish tanks and ponds as well as the pesticide DCN in soil samples. The recovery rates were 97.0-105.15% and 102.2-106.48%, and the relative standard deviations were 0.63-1.45% and 0.29-1.69%, respectively. In addition, F3B and F3Y can be made into fluorescent test papers for the visual detection of NFAs and DCN, respectively. Combined with experiments and density functional theory calculations, the mechanism of fluorescence quenching of MOFs by target analytes was also revealed.
More Related Videos
Related Concept Videos
2° Amines to N-Nitrosamines: Reaction with NaNO2
Aryldiazonium Salts to Azo Dyes: Diazo Coupling

