Related Experiment Video
Updated: Aug 22, 2025

Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS
Published on: March 14, 2013
Simultaneous profiling and quantification of 25 eicosanoids in human serum by ultrahigh-performance liquid
Yuanyuan Lu1, Zhitong Mai2, Hongxia Zhou3
1Guangzhou KingMed Center for Clinical Laboratory Co.Ltd, Guangdong, 510000, Gaungzhou, People's Republic of China.
Abstract:
The eicosanoid metabolic pathway is responsible for mediating the production of various inflammatory factors that are closely related to the development and resolution of inflammation. In biological matrices, the major quantifying obstacles were shown to be the oxidation and low quantities of eicosanoids and their metabolites. This study aimed to develop a reliable, sensitive ultrahigh-performance liquid chromatography coupled to a tandem mass spectrometry (UPLC-MS/MS) method to quantify eicosanoids in human serum. Solid-phase extraction (SPE) was used for sample preparation. The approach employed continuous ionization polarity switching. The target eicosanoids showed good linearity over the investigated concentration range (r2 > 0.99). The recovery rates were over 64.5%, and the matrix effects ranged from 73.0 to 128.0%. The limits of quantification were 0.048 ~ 0.44 ng/mL. For the broad concentration range, the CV % for accuracy and precision were less than ± 20%. We successfully applied this method to rapidly analyse 74 serum samples from severe influenza pneumonia, severe bacterial pneumonia and healthy individuals. Eicosanoid-related metabolite concentrations were quantified within a range similar to those of previously published articles. Compared to healthy individuals, our application found that 20-HETE, 14,15-EET and 11,12-EET were upregulated in severe influenza pneumonia patients, while LTB4 was downregulated. 8-HETE and 5-HETE were upregulated in severe bacterial pneumonia patients, while LTE4 was downregulated. This approach provides a means for monitoring the low quantities of eicosanoids in biological matrices, and our finding that different characteristic metabolite profiles may help discriminate the induction of severe pneumonia patients.
More Related Videos
09:26Cellular Lipid Extraction for Targeted Stable Isotope Dilution Liquid Chromatography-Mass Spectrometry Analysis
Published on: November 17, 2011
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
High-Resolution Mass Spectrometry (HRMS)