Related Experiment Video
Updated: Aug 22, 2025

High Frequency Ultrasound for the Analysis of Fetal and Placental Development In Vivo
Published on: November 8, 2018
Does ultrasound guidance during dilation and curettage for first trimester missed abortion reduce complication rates?
Adiel Cohen1, Gilad Karavani2, Amit Zamir3
1Department of Obstetrics and Gynecology, Faculty of Medicine, Hadassah Medical Organization, Hebrew University of Jerusalem, Jerusalem, Israel - adielic@gmail.com.
Background:
Dilation and curettage (D&C) may be performed with or without transabdominal ultrasound guidance. The aim of this study was to evaluate the association between the use of ultrasound guidance during D&C for first trimester missed abortion (MA) and D&C related complication rates.
Methods:
A retrospective cohort study included women in the age of 20-45 years, who underwent D&C for first-trimester MA in a hospital-based setting between 2013-2019. The study population was divided into two groups: the study group which included women who underwent D&C with ultrasound guidance (US group) and the control group, which included women who underwent D&C without ultrasound guidance (N-US group). Gynecologic, obstetric, and operative related data were collected from electronic medical records.
Results:
Three-hundred and seventy-eight women were included in the study, 86 women in the US group and 292 women in N-US group. Baseline maternal characteristics and procedure-related characteristics did not differ between the groups. No significant difference between the US group and N-US group was shown when comparing D&C related complications, including retained products of conception rate (2.3% vs. 5.5%, respectively; P=0.385), uterine perforation rate (1.2% vs. 0.3%, respectively; P=0.404), and the total complication rate (8.1% vs. 12.3%, respectively; P=0.338). In a multivariate analysis, the use of ultrasound guidance during D&C was not found to be associated with lower complication rate (adjusted odds ratio [aOR] 95% confidence interval [CI] 1.468 [0.578-3.729], P=0.419).
Conclusions:
Performance of D&C under ultrasound guidance for first-trimester MA, in a hospital-based setting, was not associated with lower complication rate, suggesting that the common practice of performing D&C without the use of ultrasound is an acceptable approach.
Related Concept Videos
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Imaging Studies II: Ultrasonography