Related Experiment Video
Updated: Aug 22, 2025

Normothermic Negative Pressure Ventilation Ex Situ Lung Perfusion: Evaluation of Lung Function and Metabolism
Published on: February 14, 2022
Interpretation and use of intraoperative protective ventilation parameters: a scoping review
Alejandro Placenti1, Franco Fratebianchi1
1Hospital de Clínicas José de San Martín, Argentina.
Abstract:
Thirty years ago, the traditional approach to mechanical ventilation consisted of the normalization of PaCO2 and pH at the expense of using a tidal volume (VT) of 10-15 mL kg-1. But then, the use of 6-8 mL kg-1 became a dogma for ventilating patients either with acute respiratory distress syndrome (ARDS) or without lung disease in the operating theatre. It is currently recognized that even low tidal volumes may be excessive for some patients and insufficient for others, depending on its distribution in the aerated lung parenchyma. To carry out intraoperative protective mechanical ventilation, medical literature has focused on positive end expiratory pressure (PEEP), plateau pressure (Paw plateau), and airway driving pressure (ΔPaw). However, considering its limitations, other parameters have emerged that represent a better reflection of isolated lung stress, such as transpulmonary pressure (PL) and transpulmonary driving pressure (ΔPL). These parameters are less generalized in clinical practice due to the requirement of an oeso-phageal balloon for their measurement and therefore their cumbersome application in the operating theatre. However, its study helps in the interpretation of the rest of the ventilator pressures to optimize intraoperative mechanical ventilation. This article defines and develops protective ventilation parameters, breaks down their determinants, mentions their limitations, and offers recommendations for their use intraoperatively.
Related Concept Videos
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...

