Related Experiment Video
Updated: Aug 22, 2025

Structured Approach to Colonoscopy Technique Optimization: A Single-Center Experience with Novice Endoscopists
Published on: July 11, 2025
Feasibility of Rescue Colonoscopy Using a Short-type Enteroscope (SIF-H290S) without Overtube after Incomplete
Yorinari Ochiai1, Hiroyuki Odagiri1, Junnosuke Hayasaka1
1Department of Gastroenterology, Toranomon Hospital, Tokyo, Japan.
Objectives:
Recently, a newly designed short-type single-balloon enteroscope (SBE), SIF-H290S, has been developed with a smaller outer diameter and a longer working length than conventional colonoscopes. It has passive bending and high-force transmission, making insertion easier. However, it is difficult to perform rescue colonoscopy with an SBE after incomplete colonoscopy in the same session. Therefore, this study evaluated the feasibility of consecutive rescue colonoscopy using SIF-H290S without overtube after incomplete colonoscopy.
Methods:
This was a single-center retrospective study. We included 19 rescue colonoscopies (19 patients) with SIF-H290S without overtube performed by 11 endoscopists in the SIF group and 38 rescue colonoscopies (38 patients) using a small-caliber colonoscope (PCF-PQ260L) were randomly selected for the control group from procedures performed by the same 11 endoscopists. We compared the cecal intubation rate and other outcomes, such as insertion time, between the two groups.
Results:
The median age of the patients was 72 and 69 years, with 8 and 26 males in the SIF and control groups, respectively. The median body mass index was 21.6 and 22.7 kg/m2 in the SIF and control groups, respectively. There were no significant differences in the patient backgrounds between the groups, except for the reason for incomplete colonoscopy (p = 0.048). The cecal intubation rate was 78.9% (15/19 procedures) and 92.1% (35/38 procedures) in the SIF and control groups, respectively.
Conclusions:
This study revealed the real-world experience and feasibility of rescue colonoscopy using SIF-H290S, which could be a potential rescue device option after incomplete colonoscopy.
More Related Videos
15:49Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
08:26Clinical Application of Single-Surgeon, Three-Port, Laparoscopic Resection for Colorectal Cancer with Natural Orifice Specimen Extraction
Published on: March 24, 2023
Related Concept Videos
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures III: Video Capsule Endoscopy
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Endoscopic Procedures V: ERCP
Patient...