Enhancing Electrode Location Assessment in Cochlear Implantation via Computed Tomography Image Fusion
Published on: January 17, 2025
One Click Is Not Enough: Anatomy-Based Fitting in Experienced Cochlear Implant Users.
Anja Kurz1, Franz-Tassilo Müller-Graff, Rudolf Hagen
1Department of Otolaryngology, University Hospital Würzburg, Comprehensive Hearing Center, Würzburg, Germany.
Anatomy-based fitting (ABF) improved speech perception for cochlear implant (CI) users. This new method enhanced auditory benefit and device acceptance, particularly for those with longer electrode arrays or dissatisfaction with previous fittings.
Area of Science:
- Audiology
- Medical Imaging
- Neurosurgery
Background:
- Cochlear implant (CI) technology offers significant auditory rehabilitation for individuals with severe to profound hearing loss.
- Current fitting methods may not fully optimize device performance for all users, necessitating advanced approaches.
- Anatomy-based fitting (ABF) presents a novel strategy to personalize CI audio processor settings.
Purpose of the Study:
- To evaluate a new methodological approach for applying anatomy-based fitting (ABF) in experienced cochlear implant (CI) users.
- To assess the impact of ABF on speech perception and user-reported auditory benefit.
- To determine the acceptance criteria for ABF in CI users with varying device configurations.
Main Methods:
- Three experienced unilateral and bilateral CI users with postlingual hearing loss participated.
- Postoperative imaging (Dyna CT) and precise electrode positions were integrated into fitting software.
- Individual frequency bandwidths were adapted within the audio processor using the new ABF procedure.
Main Results:
- ABF mapping resulted in superior speech perception in quiet and noise compared to standard clinical fitting.
- ABF was accepted by CI users even with unequal bilateral array insertion depths and lengths.
- Acceptance of ABF was contingent on the first electrode contact being below 230 Hz.
Conclusions:
- ABF mapping enhances speech understanding and auditory benefit in experienced CI users.
- This method improves device acceptance, especially for users with longer electrode arrays or previous dissatisfaction.
- Further large-scale randomized trials are warranted to confirm long-term outcomes of ABF mapping.