Finite Element Study of Stress Distribution with Tooth-Supported Mandibular Overdenture Retained by Ball Attachments
Nour M T Ajaj Al-Kordy1, Mohannad H Al-Saadi1
1Department of Removable Prosthodontics, Faculty of Dental Medicine, Damascus University, Damascus, Syria.
Objective:
The removable partial denture must keep health of the remaining teeth and the supporting tissues through the distribution of chewing forces on the abutment teeth and alveolar process.This study aimed to evaluate stress distribution with canines-supported mandibular overdenture retained by two different attachment types: ball attachments or resilient telescopic crowns.
Materials And Methods:
Two 3-dimensional finite element models consisting of the cortical mandible bone, cancellous mandible bone, oral mucosa, canines, periodontal ligaments, the two attachment types, and overdenture were simulated. The models were imported into the mathematical analysis software Ansys Workbench V 15.0. All materials were considered to be homogeneous, isotropic, and linearly elastic. A vertical bilateral load of 120 N was applied to the central fossa of the first molars. The von Mises stress was calculated for canines, cortical, and cancellous bone.
Results:
The maximum von Mises stress of the ball attachments model was 35.61, 4.28, 7.82, and 1.29 MPa for canines, cortical alveolar bone of canines, cortical alveolar bone at the distal end of the overdenture, and cancellous alveolar bone of canines, respectively. The maximum von Mises stress of the resilient telescopic crowns model was 39.22, 4.74, 7.06, and 1.05 MPa for canines, cortical alveolar bone of canines, cortical alveolar bone at the distal end of the overdenture, and cancellous alveolar bone of canines, respectively.
Conclusion:
Resilient telescopic crowns distribute the stresses between canines, alveolar bone of canines, and overdenture supporting alveolar bone. Ball attachments transfer less stress to the canines and cortical alveolar bone of the canines, but more stress to the cancellous alveolar bone of canines and alveolar bone at distal end of the overdenture. Resilient telescopic crowns are preferred over ball attachment when the abutment teeth have good periodontal support.
Related Concept Videos
Flexural Stress
Hooke's Law states that within the material's elastic limits, stress is directly proportional to strain. In a member experiencing a bending moment, the strain at any point is relative to...
Applications of Stress
The...
Eccentric Axial Loading in a Plane of Symmetry
Stress: General Loading Conditions
The shearing force, possessing potential directionality within the plane of the section, is simplified into two component forces running parallel to the x and y axes....
Transformation of Plane Stress
Stresses under Combined Loadings
The process begins by slicing the tube at critical points and analyzing the internal forces and stress components at these sections, focusing on the centroid. Normal stresses, generated by axial forces and bending moments, are either compressive or tensile and vary across the section from...