Related Experiment Video
Updated: Aug 22, 2025

Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
Published on: February 23, 2024
Comparison of detection performance of soft tissue calcifications using artificial intelligence in panoramic
Yool Bin Song1, Ho-Gul Jeong2, Changgyun Kim2,3
1Department of Advanced General Dentistry, Yonsei University College of Dentistry, 50-1 Yonsei-Ro, Seodaemun-Gu, Seoul, 03722, Republic of Korea.
Abstract:
Artificial intelligence (AI) is limited to teeth and periodontal disease in the dental field, and is used for diagnosis assistance or data analysis, and there has been no research conducted in actual clinical situations. So, we created an environment similar to actual clinical practice and conducted research by selecting three of the soft tissue diseases (carotid artery calcification, lymph node calcification, and sialolith) that are difficult for general dentists to see. Therefore, in this study, the accuracy and reading time are evaluated using panoramic images and AI. A total of 20,000 panoramic images including three diseases were used to develop and train a fast R-CNN model. To compare the performance of the developed model, two oral and maxillofacial radiologists (OMRs) and two general dentists (GDs) read 352 images, excluding the panoramic images used in development for soft tissue calcification diagnosis. On the first visit, the observers read images without AI; on the second visit, the same observers used AI to read the same image. The diagnostic accuracy and specificity for soft tissue calcification of AI were high from 0.727 to 0.926 and from 0.171 to 1.000, whereas the sensitivity for lymph node calcification and sialolith were low at 0.250 and 0.188, respectively. The reading time of AI increased in the GD group (619 to 1049) and decreased in the OMR group (1347 to 1372). In addition, reading scores increased in both groups (GD from 11.4 to 39.8 and OMR from 3.4 to 10.8). Using AI, although the detection sensitivity of sialolith and lymph node calcification was lower than that of carotid artery calcification, the total reading time of the OMR specialists was reduced and the GDs reading accuracy was improved. The AI used in this study helped to improve the diagnostic accuracy of the GD group, who were not familiar with the soft tissue calcification diagnosis, but more data sets are needed to improve the detection performance of the two diseases with low sensitivity of AI.
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
X-ray Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...

