Related Experiment Video
Updated: Aug 22, 2025

Quantification of Metal Leaching in Immobilized Metal Affinity Chromatography
Published on: January 17, 2020
A Fully Integrated, Ready-to-Use Distance-Based Chemosensor for Visual Quantification of Multiple Heavy Metal Ions
Gaobo Wang1, Jiaheng Li1, Siying Wu1
1Department of Biomedical Engineering, City University of Hong Kong, Hong Kong Special Administrative Region999077, China.
Abstract:
Point-of-care devices offering quantitative results with simple steps would allow great useability for untrained end-users. Here, we report a ready-to-use chemosensor integrating automatic sample metering, on-chip reaction, gravitational-magnetic separation, and a distance-based readout for visual quantification of multiple heavy metal ions. Deoxyribozymes (DNAzymes), probe-modified magnetic microparticles (MMPs), and polystyrene microparticles (PMPs) are preloaded into a microfluidic chip and freeze-dried. After the water sample is collected with automatic volume metering, the particles are resuspended, and the MMPs and PMPs hybridize with DNAzyme at its two termini, forming the "MMPs-DNAzyme-PMPs" structure. When target metal ions are present, the DNAzymes are cleaved, yielding an increased number of free PMPs. All on-chip reactions are controlled by stopping the liquid flow at capillary valves and bursting it with hand-controlled tilting. Using the chip with a gravitational-magnetic separator, the free PMPs are separated from "MMPs-DNAzyme-PMPs" and accumulate into the trapping channel with a nozzle, forming a visual bar with growing distances proportional to the concentration of target metal ions. The achieved limit of detection (LOD) values for Cu2+ (103.1 nM), Pb2+ (69.5 nM), and Ag+ (793.6 nM) are below the maximum contamination levels. High selectivity of 100-fold, 200-fold, and 20-fold against interference is obtained. Moreover, by integrating three identical channels in parallel, simultaneous detection of the above-mentioned heavy metal ions in fresh and tap water samples is also achieved with high accuracy. Together, this fully integrated and easily operated platform embodies excellent potential for rapid, on-site sensing by unskilled users.
More Related Videos
09:33An Anaerobic Biosensor Assay for the Detection of Mercury and Cadmium
Published on: December 17, 2018
10:31Detection and Recovery of Palladium, Gold and Cobalt Metals from the Urban Mine Using Novel Sensors/Adsorbents Designated with Nanoscale Wagon-wheel-shaped Pores
Published on: December 6, 2015
Related Concept Videos
Complexometric Titration: Overview
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
High-Performance Liquid Chromatography: Types of Detectors
Extraction: Advanced Methods
EDTA: Direct, Back-, and Displacement Titration
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides...
EDTA: Indirect and Alkalimetric Titration