Algebraic Persistent Fault Analysis of SKINNY_64 Based on S_Box Decomposition

Xing Fang1, Hongxin Zhang1,2,3, Danzhi Wang1

  • 1School of Electronic Engineering, Beijing University of Posts and Telecommunications, Beijing 100876, China.

Related Concept Videos

Unsymmetric Loading of Thin-Walled Members: Problem Solving01:07

Unsymmetric Loading of Thin-Walled Members: Problem Solving

The shear center of a channel section with uniform thickness, height, and width, is determined by computing the shear force in the member and calculating the moments of inertia of the sections.
To compute the shear forces, find the shear flow at a specific distance from the endpoint using the vertical shear and the moment of inertia values. The total shear force on the flange is calculated by integrating the shear flow from one end of the flange to the other.
Next, calculate the moments of...
149
Shearing Stresses in a Beam: Problem Solving01:14

Shearing Stresses in a Beam: Problem Solving

A cantilever beam with a rectangular cross-section under distributed and point loads experiences shearing stresses. The analysis begins by identifying the loads acting on the beam. Then, the reactions at the beam's fixed end are calculated using equilibrium equations. The vertical reaction is a combination of the distributed and point loads, while the moment reaction is the sum of their moments. The shear force distribution along the beam, resulting from these loads, is established by...
284
Power System Three-Phase Short Circuits01:21

Power System Three-Phase Short Circuits

Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
137
Thin-Walled Hollow Shafts01:15

Thin-Walled Hollow Shafts

In analyzing a thin-walled hollow shaft subjected to torsional loading, a segment with width dx is isolated for examination. Despite its equilibrium state, this segment faces torsional shearing forces at its ends. These forces are quantitatively described by the product of the longitudinal shearing stress on the segment's minor surface and the area of this surface, leading to the concept of shear flow. This shear flow is consistent throughout the structure, indicating a uniform distribution...
227
Bus Impedance Matrix01:24

Bus Impedance Matrix

Calculating subtransient fault currents for three-phase faults in an N-bus power system involves using the positive-sequence network. When a three-phase short circuit occurs at a specific bus, the analysis uses the superposition method to evaluate two separate circuits.
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
156
Fault Types01:18

Fault Types

When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
117