Related Experiment Video
Updated: Aug 22, 2025

High-throughput, Robust and Highly Time-flexible Method for Surface Sterilization of Arabidopsis Seeds
Published on: October 4, 2021
Development of Vacuum-Steam Combination Heating System for Pasteurization of Sprout Barley Powder
Seon Ho Hwang1, Sung Yong Joe2, Jun-Hwi So1
1Department of Smart Agriculture Systems, Chungnam National University, Daejeon 34134, Korea.
Abstract:
The processing of sprout vegetables in powder form has been known to extend the shelf-life by retaining nutritional values; however, sprout powder products were exposed to a variety of contaminants, such as microbial contaminants, during processing and storage. Therefore, the proper treatment for removing the contaminants in the powder was required without compromising their quality properties. This study was conducted (1) to determine a suitable pasteurization method for sprout barley powder, and (2) to investigate the effect of vacuum-steam heating combination treatment on the quality change and the lethality of microorganisms in sprout barley powder. The heating pattern of sprout barley powder was elucidated with a vacuum-thermal combination system consisting of a vacuum chamber, overhead stirrer, far-infrared heater, and PID (Proportional-Integral-Differential) controller. In addition, the mixing patterns of sprout barley powder, depending on the types of stirring blades, were evaluated by discrete element modeling using EDEM™ software. The vacuum-steam combination heating system was fabricated using the investigated pre-design factors. The quality change in sprout barely powder was evaluated by measuring the microbial inactivation, CIE values (L*, a*, b*, ΔE), and water activity (aw). During the pasteurization process, steam could be directly injected into the chamber at regular intervals for two hours to transfer moisture and heat to the powder. By combining steam and vacuum conditions, the population of E. coli O157:H7 in the powder was reduced by 4.33 log CFU/g, eliminating all E. coli O157:H7 in the powder. In addition, the water activity (aw) of the powder was significantly decreased in a vacuum pressure environment without the quality deterioration.
Related Concept Videos
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Physical Methods for Controlling Microbial Growth: Temperature
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Vaporization

