Related Experiment Video
Updated: Aug 22, 2025

Screening of Axonal Degeneration in Carpal Tunnel Syndrome Using Ultrasonography and Nerve Conduction Studies
Published on: January 11, 2019
A Proposed Safe Electromyographic Needle Insertion Technique for the Flexor Pollicis Longus Muscle Using Arterial
Min Seok Kang1, Dong Hwee Kim1, Ki Hoon Kim1
1Department of Physical Medicine and Rehabilitation, Korea University Ansan Hospital, 123 Jeokgeum-ro, Danwon-gu, Ansan-si 15355, Gyeonggi-do, Korea.
Abstract:
Electromyographic needle access to the flexor pollicis longus (FPL) is challenging because of the risk of injuries to the superficial radial nerve (SRN) or radial artery (RA), which run close to the FPL. This study aimed to investigate the safe electromyographic needle insertion point of the FPL using a newly proposed RA pulse palpation method. Fifty forearms of 25 healthy individuals were studied. At the junction of the middle and distal third of the forearm, an RA pulse was palpated, and 5 mm lateral to the pulse was determined as the preliminary needle insertion point. The distance from the vertical virtual needle pathway to the RA and SRN was measured using ultrasonography. In ultrasonography, the distances from the needle pathway to the RA and the SRN were 3.4 ± 0.8 (range, 2.1-6.0) and 5.9 ± 1.8 (range, 2.4-9.4) mm, respectively. The depth of the FPL muscle was 8.4 ± 1.7 mm. Electromyographic needle insertion into the FPL can be safely performed using the RA palpation method. The needle insertion point is 5 mm lateral to the RA pulse at the level between the middle and distal third of the forearm.
Related Concept Videos
Pulse Assessment Sites
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Pulse
The pulse serves as a clinical...
Assessment of blood pressure in brachial artery(two-step method)