Study on the Difference of Human Body Balance Stability Regulation Characteristics by Time-Frequency and Time-Domain

Xinze Cui1, Baosen Fu2, Siqi Liu1

  • 1Department of Kinesiology, Shenyang Sport University, Shenyang 110115, China.

Related Concept Videos

Time-Domain Interpretation of PD Control01:07

Time-Domain Interpretation of PD Control

Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
166
Discrete Fourier Transform01:15

Discrete Fourier Transform

The Discrete Fourier Transform (DFT) is a fundamental tool in signal processing, extending the discrete-time Fourier transform by evaluating discrete signals at uniformly spaced frequency intervals. This transformation converts a finite sequence of time-domain samples into frequency components, each representing complex sinusoids ordered by frequency. The DFT translates these sequences into the frequency domain, effectively indicating the magnitude and phase of each frequency component present...
374
Equilibrium and Balance01:15

Equilibrium and Balance

The inner ear assumes dual functionalities of auditory perception and equilibrium maintenance. The vestibule is the organ responsible for balance. This organ contains mechanoreceptors, specifically hair cells, endowed with stereocilia, which aid in deciphering information regarding the position and motion of our heads. Two intrinsic components, the utricle and saccule, help perceive head position, while the semicircular canals track head movement. Neurological messages initiated in the...
4.9K
Time and frequency -Domain Interpretation of Phase-lead Control01:24

Time and frequency -Domain Interpretation of Phase-lead Control

Phase-lead controllers are commonly used in various control systems to enhance response speed and stability. Adjusting the brightness on a television screen offers a practical example of phase-lead control. When contrast is enhanced, a phase-lead controller is employed. Mathematically, phase-lead control is identified when the first parameter is smaller than the second.
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
124
Time and frequency -Domain Interpretation of PI Control01:27

Time and frequency -Domain Interpretation of PI Control

Proportional-Integral (PI) controllers are essential in many control systems to improve stability and performance. They are commonly used in everyday devices like thermostats to enhance system damping and reduce steady-state error. When the zero in the controller's transfer function is optimally placed, the system benefits significantly in terms of stability and accuracy.
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
185
Frequency-Domain Interpretation of PD Control01:24

Frequency-Domain Interpretation of PD Control

Proportional-Derivative (PD) controllers are widely used in fan control systems to improve stability and performance. A fan control system can be effectively represented using a Bode plot to illustrate the impact of a PD controller through its transfer function. The Bode plot visually conveys how PD control modifies the fan's response across various frequencies, providing a frequency domain interpretation of the controller's behavior.
The proportional control gain, combined with the...
165