Related Experiment Video
Updated: Jun 21, 2026

10:39
Histochemical Staining of Arabidopsis thaliana Secondary Cell Wall Elements
Published on: May 13, 2014
41.1K
Rhodamine-Tagged Polymethacrylate Dyes as Alternative Tools for Analysis of Plant Cells
Rafał Bielas1, Justyna Wróbel-Marek2, Ewa U Kurczyńska2
1Department of Physical Chemistry and Technology of Polymers, Faculty of Chemistry, Silesian University of Technology, Strzody 9, 44-100 Gliwice, Poland.
Materials (Basel, Switzerland)
|November 11, 2022
Summary
This study developed rhodamine B-functionalized polymers using atom transfer radical polymerization (ATRP) for plant cell imaging. The polymers showed distinct cellular localization and were non-toxic to living plant tissues.
Area of Science:
- Polymer Chemistry
- Biotechnology
- Plant Science
Background:
- Atom Transfer Radical Polymerization (ATRP) is a controlled polymerization technique.
- Rhodamine B (RhB) is a fluorescent dye often used in biological imaging.
- Functionalizing polymers with fluorescent tags allows for tracking their behavior in biological systems.
Purpose of the Study:
- To synthesize RhB-functionalized polymers for plant cell visualization.
- To investigate the cellular localization and biocompatibility of these polymers in plant tissues.
- To explore the relationship between polymer properties (hydrophilicity, solvent) and fluorescence.
Main Methods:
- Synthesis of RhB-based ATRP initiator.
- Preparation of poly(2-trimethylammoniumethyl methacrylate) (PChMA), poly(2-hydroxyethyl methacrylate) (PHEMA), and poly(2-trimethylsilyloxyethyl methacrylate) (PHEMATMS).
- Determination of polymer quantum yield and fluorescence properties.
- Biological testing in plant materials (root tissues, cotyledons) to assess cellular localization and toxicity.
Main Results:
- Successful synthesis of RhB-functionalized polymers with varying fluorescence properties.
- RhB-PChMA localized in cell walls and cytoplasm/organelles of root tissues and epidermis.
- RhB-PHEMA showed broader localization in apoplast, xylem, and cytoplasm/organelles, with no observed cell death.
- RhB-PHEMATMS exhibited weak fluorescence, limiting its biological application.
Conclusions:
- RhB-functionalized polymers, particularly RhB-PChMA and RhB-PHEMA, are suitable for tracking in plant cells.
- The polymers demonstrate specific cellular localization patterns within plant tissues.
- These fluorescent polymers are non-toxic to living plant material, enabling in vivo studies.

