Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Computed Tomography01:10

Computed Tomography

4.8K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
4.8K
Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

35
DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
35
Imaging Studies II: Ultrasonography01:24

Imaging Studies II: Ultrasonography

39
IntroductionUltrasonography, or renal ultrasound, is a noninvasive medical imaging technique that uses high-frequency sound waves to visualize the kidneys, ureters, bladder, and surrounding tissues.Indications for Urinary System UltrasonographyUrinary system ultrasonography is indicated in various clinical scenarios, such as:Kidney Stones (Urolithiasis): To detect and monitor the size and presence of kidney or urinary tract stones.Hydronephrosis: To assess the dilation of the renal pelvis and...
39
Imaging Biological Samples with Optical Microscopy01:18

Imaging Biological Samples with Optical Microscopy

5.0K
Optical microscopy uses optic principles to provide detailed images of samples. Antonie van Leeuwenhoek designed the first compound optical microscope in the 17th century to visualize blood cells, bacteria, and yeast cells. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes with enhanced magnification and resolution.
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
5.0K
Ultrasound II: Endoscopic Ultrasound and FibroScan01:25

Ultrasound II: Endoscopic Ultrasound and FibroScan

178
Endoscopic Ultrasound (EUS) and FibroScan are valuable diagnostic tools in gastroenterology and hepatology, each with specific applications and techniques.
Endoscopic Ultrasound (EUS):
178
Gauss's Law: Planar Symmetry01:27

Gauss's Law: Planar Symmetry

8.1K
A planar symmetry of charge density is obtained when charges are uniformly spread over a large flat surface. In planar symmetry, all points in a plane parallel to the plane of charge are identical with respect to the charges. Suppose the plane of the charge distribution is the xy-plane, and the electric field at a space point P with coordinates (x, y, z) is to be determined. Since the charge density is the same at all (x, y) - coordinates in the z = 0 plane, by symmetry, the electric field at P...
8.1K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

A Piezo-Mimetic Ionic Hydrogel Harnessing Joint Motion for Cartilage Repair.

Advanced science (Weinheim, Baden-Wurttemberg, Germany)·2026
Same author

Numerical Simulations of In-Plane and Transmural Tear Propagations in Aortic Dissection: Possible Mechanisms Behind Dissection Progression.

Journal of biomechanical engineering·2025
Same author

Biomechanical mechanisms behind the distal false lumen enlargement after TEVAR for type b aortic dissections: A computational one-way fluid-structure interaction study.

Journal of biomechanics·2025
Same author

Quasi-Static Mechanical Biomimetics Evaluation of Car Crash Dummy Skin.

Biomimetics (Basel, Switzerland)·2024
Same author

High accuracy patient-specific 3D coronary reconstruction from angiography and intravascular optical coherence tomography.

Optics letters·2024
Same author

High-accuracy optical coherence elastography digital volume correlation methods to measure depth regions with low correlation.

Journal of biophotonics·2023
Same journal

Denoising algorithm of Φ-OTDR systems based on adaptive fractional wavelet transform denoising.

Optics express·2026
Same journal

Millisecond photon-to-photon latency and high-speed volumetric projection system for optogenetics.

Optics express·2026
Same journal

Polarization-encoded coaxial structured light for high-precision 3D surface profilometry.

Optics express·2026
Same journal

Discrete freeform optical design based on collaborative optimization of point cloud and local normals.

Optics express·2026
Same journal

Ultrafast ghost imaging with 25 GHz speckle switching and wavelength-division multiplexing.

Optics express·2026
Same journal

Atomic vapor cells fabricated by femtosecond laser welding of standard-optical-quality glass.

Optics express·2026
See all related articles

Related Experiment Video

Updated: Aug 22, 2025

Author Spotlight: Characterizing Environmental Biofilm Mechanics Using Optical Coherence Elastography and its Applications in Wastewater Treatment
04:51

Author Spotlight: Characterizing Environmental Biofilm Mechanics Using Optical Coherence Elastography and its Applications in Wastewater Treatment

Published on: March 1, 2024

1.1K

Optical coherence elastography based on inverse compositional Gauss-Newton digital volume correlation with

Hao Wu, Jiaqiu Wang, Jorge Alberto Amaya Catano

    Optics Express
    |November 11, 2022
    PubMed
    Summary
    This summary is machine-generated.

    This study presents an advanced optical coherence elastography (OCE) method using digital volume correlation (DVC) for precise biological tissue characterization. The improved technique offers higher accuracy and a larger strain range, enhancing mechanical property analysis.

    More Related Videos

    Longitudinal Morphological and Physiological Monitoring of Three-dimensional Tumor Spheroids Using Optical Coherence Tomography
    08:50

    Longitudinal Morphological and Physiological Monitoring of Three-dimensional Tumor Spheroids Using Optical Coherence Tomography

    Published on: February 9, 2019

    7.8K
    Automated 3D Optical Coherence Tomography to Elucidate Biofilm Morphogenesis Over Large Spatial Scales
    09:56

    Automated 3D Optical Coherence Tomography to Elucidate Biofilm Morphogenesis Over Large Spatial Scales

    Published on: August 21, 2019

    7.0K

    Related Experiment Videos

    Last Updated: Aug 22, 2025

    Author Spotlight: Characterizing Environmental Biofilm Mechanics Using Optical Coherence Elastography and its Applications in Wastewater Treatment
    04:51

    Author Spotlight: Characterizing Environmental Biofilm Mechanics Using Optical Coherence Elastography and its Applications in Wastewater Treatment

    Published on: March 1, 2024

    1.1K
    Longitudinal Morphological and Physiological Monitoring of Three-dimensional Tumor Spheroids Using Optical Coherence Tomography
    08:50

    Longitudinal Morphological and Physiological Monitoring of Three-dimensional Tumor Spheroids Using Optical Coherence Tomography

    Published on: February 9, 2019

    7.8K
    Automated 3D Optical Coherence Tomography to Elucidate Biofilm Morphogenesis Over Large Spatial Scales
    09:56

    Automated 3D Optical Coherence Tomography to Elucidate Biofilm Morphogenesis Over Large Spatial Scales

    Published on: August 21, 2019

    7.0K

    Area of Science:

    • Biomedical Engineering
    • Optical Imaging
    • Biomechanics

    Background:

    • Accurate characterization of biological tissue mechanics is crucial for disease diagnosis and treatment.
    • Existing optical coherence elastography (OCE) methods face limitations in strain range and accuracy.
    • Digital Volume Correlation (DVC) offers a robust framework for analyzing deformation in 3D imaging data.

    Purpose of the Study:

    • To develop and validate a novel DVC-based OCE method for enhanced mechanical property assessment of biological tissues.
    • To improve the accuracy and extend the measurable strain range of OCE.
    • To reduce systematic errors in displacement and strain measurements.

    Main Methods:

    • Implementation of a DVC-based optical coherence elastography (OCE) method.
    • Utilizing an inverse compositional Gauss-Newton (IC-GN) algorithm for data processing.
    • Incorporation of a second-order shape function to model complex deformations.

    Main Results:

    • Achieved systematic measurement errors of displacement < 0.2 voxel and strain < 4 × 10-4.
    • Demonstrated superior performance compared to conventional methods, tracking larger strain ranges up to 0.095.
    • Reduced relative error by 30-50% through the use of a second-order shape function.

    Conclusions:

    • The developed DVC-based OCE method provides highly accurate and sensitive measurements of tissue mechanical properties.
    • The second-order shape function effectively mitigates errors associated with complex deformations and speckle rigidity.
    • This advanced OCE technique shows significant potential as a valuable tool for characterizing biological tissue mechanics.