Seismic collapse risk of RC-timber hybrid building with different energy dissipation connections considering NBCC

Ikenna Odikamnoro1, Prakash S Badal1, Henry Burton2

  • 1School of Engineering, University of British Columbia, Kelowna, V1V 1V7 BC Canada.

Journal of Infrastructure Preservation and Resilience
|November 11, 2022
PubMed

Related Concept Videos

Design Example: Sustainability in Concrete Building01:26

Design Example: Sustainability in Concrete Building

As the construction industry moves towards more eco-friendly practices, concrete's adaptability and its ability to incorporate sustainable features make it a key material in the drive towards greener building solutions.
There are multiple approaches to achieve sustainability in a commercial concrete building. For instance, construct a concrete parking area under the building, utilizing pervious concrete paver blocks in open areas to facilitate rainwater collection through an underground...
216
Prismatic Beams: Problem Solving01:15

Prismatic Beams: Problem Solving

In the design of a supported timber beam subjected to a distributed load, both the beam's physical dimensions and the timber's characteristics, such as its grade and species, are critical. These factors determine the allowable stress values, which are crucial for calculating the necessary beam depth to ensure structural integrity and safety.
The design begins with analyzing the beam as a free body to identify moments and force balances, thereby determining support reactions. Next, the...
196
Internal Loadings in Structural Members: Problem Solving01:28

Internal Loadings in Structural Members: Problem Solving

When designing or analyzing a structural member, it is important to consider the internal loadings developed within the member. These internal loadings include normal force, shear force, and bending moment. Engineers can ensure that the structural member can support the applied external forces by calculating these internal loadings.
To illustrate this, let's consider a beam OC of 5 kN, inclined at an angle of 53.13° with the horizontal and supported at both ends. Determine the internal...
1.4K
Design Consideration01:22

Design Consideration

Designing a structure involves a series of considerations, primarily the material's ultimate strength, calculated through tests that measure changes under increased force until the material reaches its breaking point or limit. The ultimate load, where the material breaks, is divided by its original cross-sectional area, resulting in the ultimate normal stress or strength. The ultimate shearing stress is another significant factor taken into account.
The factor of safety is another key...
297
Types of Building Separation Joints01:23

Types of Building Separation Joints

Building separation joints divide large or complex building structures into smaller, discrete units that can move independently. These joints are categorized into three types: volume-change joints, settlement joints, and seismic separation joints.
Volume-change joints address the effects of expansion and contraction due to temperature and moisture variations. They are strategically placed at discontinuities in a building's mass where cracking is most likely and are spaced about 150 to 200...
303
Stresses under Combined Loadings01:23

Stresses under Combined Loadings

When analyzing a bent tube with a circular cross-section subjected to multiple forces, it is crucial to determine the stress distribution in order to maintain structural integrity under varied load conditions.
The process begins by slicing the tube at critical points and analyzing the internal forces and stress components at these sections, focusing on the centroid. Normal stresses, generated by axial forces and bending moments, are either compressive or tensile and vary across the section from...
222