Related Experiment Video
Updated: Aug 22, 2025

Ischemia-reperfusion Model of Acute Kidney Injury and Post Injury Fibrosis in Mice
Published on: August 9, 2013
Clinically relevant urine creatinine underestimation in the low concentration range on the Siemens Dimension Vista®
Alexandre Raynor1, Célia Raulet-Bussian1, Tiphaine Robert-Mercier1
1Département de Biochimie, Hôpitaux Universitaires Paris Nord Val de Seine - site Bichat, Assistance Publique Hôpitaux de Paris, Paris, France.
Abstract:
While considerable efforts have been accomplished to standardize the measurement of plasma creatinine (PCr), urine creatinine (UCr) has not been subject to the same scrutiny. UCr is importantly used when measuring biomarkers in spot urines, to assess urine output and variable dilution of urine samples. Here, we report underestimation of Jaffe UCr measurements on the Siemens Dimension Vista® analyzer, critically affecting samples with UCr ≤2 mmol/L. We demonstrate that this error is caused by automatic urine pre-dilution by the Vista's «urine mode», and that UCr measured in «plasma mode» without pre-dilution does not present this error. In the absence of a comprehensive solution proposed by Siemens, we propose simple formulae that can be easily implemented in a laboratory to correct these low UCr measurements. Importantly, the observed UCr underestimation can significantly influence reported results for biomarkers/UCr ratios measured in spot urine. Indeed, these results can be overestimated up to +84.4 % before correction using our formulae. This can sometimes lead to misclassification according to clinical thresholds, e.g. Kidney disease: improving global outcomes (KDIGO) guidelines for urine albumin/creatinine. This highlights the need for every clinical laboratory to assess the detection limits of their assays, including for lesser-discussed parameters such as UCr. Indeed, the error we reported here may affect other urine assays performing systematic urine pre-dilution and could have significant repercussions on the clinical management of patients.
Related Concept Videos
Serum Studies: Renal Function Tests
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...
Determination of Renal Drug Clearance: Graphical and Midpoint Methods
The graphical method involves plotting the rate of drug excretion in urine against the plasma drug concentration. By analyzing the graph, the clearance can be calculated and obtained. Drugs rapidly excreted by the kidneys exhibit a...
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Acute Kidney Injury IV: Diagnostic Studies and Prevention