Related Experiment Video
Updated: Aug 22, 2025

Two-way Valorization of Blast Furnace Slag: Synthesis of Precipitated Calcium Carbonate and Zeolitic Heavy Metal Adsorbent
Published on: February 21, 2017
Nickel removal from wastewater using electrocoagulation process with zinc electrodes under various operating
Omar A Shaker1, Safwat M Safwat2, Minerva E Matta1
1Sanitary & Environmental Engineering Division, Public Works Department, Faculty of Engineering, Cairo University, Giza, 12316, Egypt.
Abstract:
Economically feasible approaches are needed for wastewater treatment. Electrocoagulation (EC) is an electrochemical treatment method that removes various pollutants from wastewater. It has grown in popularity over conventional treatment methods, especially in industrial wastewater, due to its high performance and the ability to remove toxic compounds. However, it is crucial to reduce the costs associated with EC for widespread implementation. It is also important to decrease nickel (Ni) concentrations in wastewater to prevent potential health and environmental problems. Therefore, this study investigates Ni removal from synthetic and real wastewater using electrocoagulation. Zinc, as a novel electrode, was used as the sacrificial anode. Several operating conditions were assessed, including current density, initial pH, electrolysis time, and spacing between electrodes. The maximum Ni removal efficiency, after 90 min, reached 99.9% at a current density of 10 mA/cm2 when the pH was 9.2 and the gap distance was 4 cm. The Ni removal rate reached 94.4% and 94.9% at a 2- and 6-cm spacing, respectively, after 90 min. Anode morphology, kinetic modeling, electrical energy consumption, and cost analysis were also investigated. The type of corrosion was uniform, which is easily predicted compared to pitting corrosion. The comparison between chemical coagulation and electrocoagulation was also reported. Experimental results indicated that the maximum Ni removal rates reached 99.89% after 90 min. The optimum spacing between electrodes was 4 cm, and the optimum current density was 10 mA/cm2. Additionally, the kinetic data were best represented through the second-order Lagergren model. The results demonstrated that the electrocoagulation performance was better than that of chemical coagulation for Ni removal. The maximum electrical energy consumption was 23.79 KWh/m3 for Ni removal.
Related Concept Videos
Electrodeposition
Electrodeposition can...
Coagulation
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
Standard Electrode Potentials
Extraction: Advanced Methods
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...