Prediction of surface excess adsorption and retention factors in reversed-phase liquid chromatography from molecular
Fabrice Gritti1, Nicole Trebel2, Alexandra Höltzel2
1Waters Corporation, Instrument/Core Research/Fundamental, 34 Maple Street, Milford, MA, 01757, USA.
Abstract:
An alternative method to the classical fit of semi-empirical, statistical, or artificial intelligence-based models to retention data is proposed to predict surface excess adsorption and retention factors in liquid chromatography. The approach is based on a fundamental, microscopic description of the liquid-to-solid adsorption of analytes taking place at the interface between a bulk liquid phase and a solid surface. Molecular dynamics (MD) simulations are performed at T=300 K in a 100 Å wide slit-pore model (β-cristobalite-C18 surface in contact with an acetonitrile/water mobile phase) to quantify a priori the retention factors of small molecules expected in reversed phase liquid chromatography (RPLC). Uracil is chosen as the reference "non-retained" marker, whereas benzyl alcohol, acetophenone, benzene, and ethylbenzene are four selected retained, neutral compounds. The MD simulations allow to determine the pore-level density profiles of these five compounds, i.e., the variation of the analyte concentration as a function of distance from the silica surface. The retention factors of the retained analytes are expressed using their respective calculated surface excess adsorption relative to uracil. By definition, the retention factors are proportional to the surface excess adsorbed and the proportionality constant is directly scaled to the retention time of the "non-retained" marker. Experimentally, a 4.6 mm × 150 mm RPLC-C18 column packed with 5 μm 100 Å High Strength Silica (HSS)-C18 particles is used and the retention times of these five compounds are measured. The volume fraction of acetonitrile in water increases from 20 to 90% generating a wide range of retention factors from 0.15 to 183 at T=300 K. The results demonstrate very good agreement between the MD-predicted surface excess adsorption data and measured retention factors (R2> 0.985). A systematic error is observed as the proportionality constant is not exactly scaled to the retention time of uracil. This is most likely caused by the differences between the chemical and morphological features of the slit-pore model adopted in the MD simulations and those of the actual HSS-C18 particles: the average surface coverage with C18 chains, the geometry of the mesopores, and the pore size distribution. Specifically, the impact on RPLC retention of slight, local variations in surface chemistry (e.g., functional group density and uniformity) and how this aspect is affected by the pore space morphology (e.g., pore curvature and size) is worth investigating by future MD simulations.
More Related Videos
08:54Vibrational Spectra of a N719-Chromophore/Titania Interface from Empirical-Potential Molecular-Dynamics Simulation, Solvated by a Room Temperature Ionic Liquid
Published on: January 25, 2020
09:43Study of Short Peptide Adsorption on Solution Dispersed Inorganic Nanoparticles Using Depletion Method
Published on: April 11, 2020
Related Concept Videos
Analyte Adsorption and Distribution
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Chromatographic Methods: Terminology
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...