Related Experiment Video For Image quality
Updated: Aug 22, 2025

Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Modification of [18F]-FDG PET/CT imaging protocols in obese oncology patients: A nationwide survey
R Oliveira1, L Figueiredo2, P Costa3
1Medical Imaging and Radiotherapy Graduation Programme, School of Health - Polytechnic Institute of Porto, Portugal.
Introduction:
The use of medical imaging for diagnosis, staging and follow-up in Oncology context is incredibly important, being the use of [18F]-FDG PET/CT particularly advantageous in specific contexts like the case of obese patients. However, imaging the latter can be challenging sometimes, since their own body size may affect overall image quality and adds technical difficulties for the operator(s) performing the examination.
Methods:
This research project was developed with the aim of analysing the current personal practices of Portuguese Nuclear Medicine Technologists (NMTs) in the adaptation of 18F-FDG PET/CT oncological protocols for obese patients and comparing the results with parameters referenced in literature. A non-experimental research study was conducted using a survey delivered online to NMTs through social media platforms (Facebook® and LinkedIn®) and by sending the link directly to contacts within the research team professional and personal networks.
Results:
Answers from a total of 26 participants were obtained, with 88.5% of participants admitting modifying technical protocols in examinations for obese patients. Changes in PET protocols included an increase in the administered activity (60.9%), an increase in scan time per individual bed position (69.6%) and the use of Time-of-Flight (TOF) technology whenever available. Protocol changes in CT included increasing the mA (82.6%), raising the KVp (47.8%), the application of iterative reconstruction (69.6%) and the use of automatic exposure control (AEC) (52.2%). The remaining parameters (pitch, algorithm, slice thickness, display FOV, gantry rotation time and energy acceptance window) were claimed not to be modified by around 90% of professionals.
Conclusion:
Portuguese NMTs tend to change the [18F]-FDG PET/CT protocols for obese patients. However, while some of the parameters appear to be contradictory or redundant, others require further optimisation, especially in the CT component.
Implications For Practice:
Efforts should be made to optimize acquisition protocols used in [18F]-FDG PET/CT scans for obese patients.
More Related Videos
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...