Purpose/Objectives:
Advancements in transcatheter mitral and tricuspid valve repair have resulted in growing demands in preprocedural computed tomography (CT) imaging. Due to the introduction of multidetector CT (MDCT), shorter acquisition times as well as high rates of heart failure and arrhythmias in this specific patient population, optimal synchronization between the passage of contrast agent and data acquisition is mandatory. There is no consensus on which acquisition technique should be used in this patient population. We aimed to optimize our preprocedural CT protocol comparing bolus tracking (BT) and test bolus (TB) techniques.
Materials And Methods:
We performed a retrospective analysis on 151 patients referred for full-cycle MDCT evaluation for transcatheter tricuspid valve repair comparing BT with TB (BT n=75 TB n=75). Contrast-to-noise ratios (CNR) were obtained. Demographic data, laboratory, electrocardiographic, and transthoracic echocardiography/transoesophageal echocardiography parameters were collected from electronic health records. Also, the volume of contrast agent and saline chaser and radiation dose length product and milliampere seconds were collected.
Results:
BT and TB resulted in comparable CNR (BT: 0.47 [0.34 to 0.98]; TB: 0.51 [0.41 to 1.40]; P =0.1). BT was associated with a shorter scan duration (BT: 8.3 min [4.1 to 24.4]; TB: 13.9 min [6.2 to 41.4]; P <0.001), less radiation in terms of dose length product (BT: 1186±585; TB: 1383±679, P =0.04), and lower total volume administration (BT: 101 mL [63 to 16]; TB: 114 mL [71 to 154]; P <0.001). In patients with severely impaired ejection fraction (left ventricular ejection fraction [LVEF] ≤35%; n=65 [TB n=31; BT n=34]) using the TB technique yielded significantly better image quality in terms of CNR (TB=0.57 [0.41 to 1.07); BT=0.41 [0.34 to 0.65]; P =0.02).
Conclusion:
In patients with impaired LVEF (LVEF≤35%), the TB technique yielded significantly superior image quality and may be the preferred approach in this specific patient population. BT showed advantages in terms of shorter duration, less radiation, and lower contrast agent volume.
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Cardiac Catheterization I: Pre-Procedure Overview
Imaging Studies III: Computed Tomography