Related Experiment Video
Updated: Aug 22, 2025

Biosynthesis of a Flavonol from a Flavanone by Establishing a One-pot Bienzymatic Cascade
Published on: August 14, 2019
Chiral and achiral separation of ten flavanones using supercritical fluid chromatography. Application to bee pollen
Ana M Ares1, José Bernal1, Andrea Janvier1
1Department of Analytical Chemistry, Faculty of Sciences, I. U. CINQUIMA, Analytical Chemistry Group (TESEA), University of Valladolid, C/ Paseo de Belén 5, Valladolid E-47011, Spain.
Abstract:
The separation of ten flavanones (flavanone, 2'-hydroxyflavanone, 4'-hydroxyflavanone, 6-hydroxyflavanone, 7-hydroxyflavanone, naringenin, naringin, hesperetin, pinostrobin, and taxifolin) using supercritical fluid chromatography and considering achiral and chiral approaches has been studied in this work. For this purpose, different stationary phases and organic modifiers have been checked. Considering the achiral separation, the best results were obtained with the Lichrospher 100 Diol column at 35 °C, 3 mL/min, 150 bar and a gradient of 2-propanol from 5% to 50%. The baseline separation of the ten compounds was achieved in 18 min. Using the chiral column Chiralpak AD, the separation of the ten pairs of enantiomers was obtained in 32 min. In this case, the chromatographic conditions were 30 °C, 3 mL/min, 150 bar and the organic modifier was a mixture ethanol/methanol (80:20) containing 0.1% of trifluoroacetic acid applied in an elution gradient from 15% to 50%. The applicability of the proposed chiral method was assessed by analysing bee pollen samples and 2S-pinostrobin was determined in some of them.
Related Concept Videos
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Principles Of Column Chromatography
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...