[Qualification of low temperature vaporized hydrogen peroxide sterilization: Towards greater harmonization of
R Van Den Broucke1, A Maurin1, P Tilleul2
1Sorbonne université, pharmacie à usage intérieur - unité fonctionnelle de stérilisation, hôpital Pitié-Salpêtrière, Assistance Publique des hôpitaux de Paris (AP-HP), Paris, France.
Objectives:
Comparing performance qualification procedures for low temperature vaporized hydrogen peroxide sterilization. Assessing conformity with draft standard ISO/DIS 22441.
Methods:
Qualification reports from several providers have been compared according to specific criteria: choices of cycles, loads, sterile barrier systems, probes, biological and chemical indicators; checking of packaging integrity and exposure to sterilizing agent.
Results:
Six out of 8 reports based on 4 distinct sterilizers have been performed by third-party providers. Routine and process challenge devices are respectively used in 6 and 3 of these reports. Sizes and masses are never mentioned whereas load configuration is always specified. All reports use at least one biological indicator and 50% of them use one chemical indicator at a minimum. Most frequent wrapping materials are Ultra® and Tyvek® bags (respectively 50% and 37.5% of reports). Each qualification monitors per process pression and temperature, and 37.5% of them also quantify hydrogen peroxide concentration. Packaging integrity and environmental exposure are checked in respectively 50% and 12.5% of all reports. All reports have received providers approval.
Conclusion:
Qualification procedure is based on steam sterilization NF EN 14937 standard, which seems unsuitable for low temperature process. The lack of autonomy, the heterogeneity of loads and measurement choices reveal a low harmonization of practices. New standard should dispel the doubts about this heterogeneity.
Related Concept Videos
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Physical Methods for Controlling Microbial Growth: Temperature
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Vaporization
Physical Methods for Controlling Microbial Growth: Radiation and Filtration