Improvement of proton beam range uncertainty in breast treatment using tissue samples
Xiangli Cui1,2, Kyungwook Jee3, Man Hu4
1Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, 230031, People's Republic of China.
Abstract:
Objective.Proton therapy after breast-conserving surgery (BCS) can substantially reduce the dose to lung and cardiac structures. However, these dosimetric benefits are subject to beam range uncertainty in patient. The conversion of the CT-Hounsfield unit (HU) into relative stopping power (RSP) is the primary contribution to range uncertainty. Hence, an accurate HU-RSP conversion is essential.Approach.Real tissue samples, including muscle and adipose, were prepared. The water equivalent path length (WEPL) of these samples was measured under homogeneous conditions using a 12-diode detector array of our time-resolvedin vivorange verification system (IRVS). The HU-RSP conversion was improved using the measured WEPL and HU for adipose tissue. The measured WEPL values were compared with the treatment planning calculation results based on the stoichiometric CT-HU calibration technique. The effect was investigated for both with and without adipose tissue in HU-RSP conversion.Main results.The IRVS was calibrated based on the solid water phantom. The relative differences in WEPL (RSP) between measurements and calculations for muscle, adipose, and water was -1.19% (-0.75%), -4.25%(-4%), and -0.23%(-0.07%), respectively. Based on the improved HU-RSP conversion, the relative differences in WEPL was reduced to -0.97%(-0.62%), -1.50%(-1.46%), and -0.22% (0.00%), respectively.Significance.The WEPL deviation of adipose tissue is larger than the testing limit of 3.5% for beam range robustness in current clinical practice. However, the improved HU-RSP conversion reduced this deviation. The main component of breast tissue is adipose. Hence, the proton treatment of BCS can be undershooting if no proper measures are taken against this specific uncertainty.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
06:33Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
Published on: July 29, 2013