Related Experiment Video
Updated: Aug 21, 2025

09:20
Step-by-Step Stapedotomy through Transcanal Exclusive Endoscopic Approach
Published on: March 5, 2022
5.4K
"Hot" vs "Cold" endoscopic stapes surgery: a matched case-control study
Giulia Molinari1,2, Ignacio Javier Fernandez1,2, Claudio Melchiorri3
1Department of Otolaryngology, Head and Neck Surgery, Policlinico S. Orsola-Malpighi, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Via Massarenti, 9, Bologna, Italy.
Summary
Endoscopic stapes surgery (ESS) using either CO2 fiber laser or microdrill shows similar hearing outcomes and complication rates. Both techniques are safe and effective for treating otosclerosis.
Area of Science:
- Otolaryngology
- Surgical Innovation
- Audiology
Background:
- Otosclerosis is a common cause of conductive hearing loss.
- Stapes surgery is a standard treatment for otosclerosis.
- Advancements in surgical technology offer new approaches to stapes surgery.
Purpose of the Study:
- To compare hearing results and complication rates of endoscopic stapes surgery (ESS) for otosclerosis.
- To evaluate the efficacy of CO2 fiber laser versus microdrill techniques in ESS.
Main Methods:
- A case-control study matched patients based on year of surgery, preoperative air-bone gap, sex, and age.
- Audiological data and complication rates were compared between CO2 fiber laser ESS and traditional microdrill ESS groups.
- 46 patients undergoing ESS for otosclerosis were included.
Main Results:
- Operative time was longer for the CO2 fiber laser group (65 min) compared to the microdrill group (45 min).
- Both groups showed similar postoperative air-conduction pure-tone averages (AC-PTA).
- The laser group exhibited higher high-frequency bone conduction and improved BC-PTA at 2000 Hz, suggesting a potential overclosure effect.
Conclusions:
- Endoscopic stapes surgery (ESS) is a safe and effective treatment for otosclerosis.
- Both CO2 fiber laser and microdrill techniques yield similar functional hearing outcomes.