Context-Aware, Reference-Free Local Motion Metric for CBCT Deformable Motion Compensation
H Huang1, J H Siewerdsen1,2, W Zbijewski1
1Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD.
Abstract:
Deformable motion is one of the main challenges to image quality in interventional cone beam CT (CBCT). Autofocus methods have been successfully applied for deformable motion compensation in CBCT, using multi-region joint optimization approaches that leverage the moderately smooth spatial variation motion of the deformable motion field with a local neighborhood. However, conventional autofocus metrics enforce images featuring sharp image-appearance, but do not guarantee the preservation of anatomical structures. Our previous work (DL-VIF) showed that deep convolutional neural networks (CNNs) can reproduce metrics of structural similarity (visual information fidelity - VIF), removing the need for a matched motion-free reference, and providing quantification of motion degradation and structural integrity. Application of DL-VIF within local neighborhoods is challenged by the large variability of local image content across a CBCT volume, and requires global context information for successful evaluation of motion effects. In this work, we propose a novel deep autofocus metric, based on a context-aware, multi-resolution, deep CNN design. In addition to the inclusion of contextual information, the resulting metric generates a voxel-wise distribution of reference-free VIF values. The new metric, denoted CADL-VIF, was trained on simulated CBCT abdomen scans with deformable motion at random locations and with amplitude up to 30 mm. The CADL-VIF achieved good correlation with the ground truth VIF map across all test cases with R2 = 0.843 and slope = 0.941. When integrated into a multi-ROI deformable motion compensation method, CADL-VIF consistently reduced motion artifacts, yielding an average increase in SSIM of 0.129 in regions with severe motion and 0.113 in regions with mild motion. This work demonstrated the capability of CADL-VIF to recognize anatomical structures and penalize unrealistic images, which is a key step in developing reliable autofocus for complex deformable motion compensation in CBCT.
Related Concept Videos
Curvilinear Motion: Rectangular Components
As the car advances, its position evolves over time. Quantifying the car's velocity involves computing the...
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it...
Absolute Motion Analysis- General Plane Motion
As the drone's propellers rotate, an upward force is generated that counteracts the force of gravity, enabling the drone to lift off from the ground. This initial movement of the drone is along a straight path, representing a form of translational motion. In this phase, every point on the...
Curvilinear Motion: Normal and Tangential Components
The positive direction of the t-axis aligns with the increasing position of the car along the curved path, denoted by the unit vector ut. Simultaneously, the n-axis, perpendicular to the t-axis, dissects the curved path into differential arc segments, each forming the arc of a circle with a radius of...
Relative Motion Analysis - Acceleration
Relative Motion Analysis - Velocity
When an external force is exerted, it sets the crank into a rotational movement. This, in turn, instigates the motion of the connecting rod, leading to what is referred to as a general plane motion. This process involves two key points - point A on the connecting rod...