Related Experiment Video
Updated: Aug 21, 2025

Novel Diagnostics in Revision Arthroplasty: Implant Sonication and Multiplex Polymerase Chain Reaction
Published on: December 3, 2017
Physician Use of Multiple Criteria to Diagnose Periprosthetic Joint Infection May Be Less Accurate Than the Use of an
Carl Deirmengian1,2, Alex McLaren3, Carlos Higuera4
1Orthopaedic Surgery, The Rothman Orthopaedic Institute, Philadelphia, USA.
Abstract:
Introduction Multiple-criterion scoring systems for periprosthetic joint infection (PJI) can be algorithmically implemented in research, diagnostically outperforming individual tests. This improved performance may be lost in the practice setting, where clinicians rarely utilize strict algorithms. The ability of physicians to interpret multiple criteria for PJI and confront the complexity of combining them into a final diagnosis has never been studied. This study assessed the diagnostic characteristics of physicians using multiple criteria to diagnose PJI and compared the physicians' diagnostic accuracy to that of individual tests. Methods A total of 12 physicians, including academic arthroplasty surgeons (N=4), community arthroplasty surgeons (N=4), and infectious disease (ID) specialists (N=4) were asked to use their routine clinical diagnostic practice to assign a diagnosis to 277 clinical vignettes using multiple preoperative laboratory criteria for PJI. The undecided rate, interobserver agreement, and accuracy of physicians were characterized relative to the 2013 Musculoskeletal Infection Society (MSIS) gold standard and compared to the accuracy of each individual laboratory test for PJI. Results Physicians interpreting multiple criteria for PJI demonstrated high undecided diagnosis rates (mean=23.5%), poor interobserver agreement (kappa range=0.49-0.63), and mean accuracy of 90.8% (range:85.8%-97.4%) compared to the 2013 MSIS gold standard. The group of academic arthroplasty surgeons had a lower rate of undecided diagnoses than community arthroplasty surgeons (16.2% vs. 29.1%; p<0.0001) or ID specialists (16.2% vs. 25.1%; p<0.0001). Academic arthroplasty surgeons also exhibited a higher interobserver agreement than community arthroplasty surgeons (kappa = 0.63 (95%CI:0.59-0.68) vs. 0.49 (95%CI:0.44-0.54)). Mean physician accuracy (90.8%) was inferior to the alpha-defensin laboratory test (96.0%;p=0.0034) and the alpha-defensin lateral-flow test (94.6%;p=0.036), comparable to synovial fluid white blood cells (SF-WBC) (93.3%;p=0.17) and synovial fluid polymorphonuclear cell % (SF-PMN%) (94.0%;p=0.11), and superior to the erythrocyte sedimentation rate (ESR) (86.2%;p<0.0001) and C-reactive protein (CRP) (84.6%;p<0.0001). Only two academic arthroplasty surgeons in this study were able to outperform every individual test for PJI by combining multiple criteria to make a diagnosis. Conclusion Although multiple-criterion scoring systems may outperform individual tests for diagnosing PJI in the research setting, it appears that the complexity of using multiple tests to diagnose PJI causes indecision and variability among physicians. Physician use of multiple preoperative criteria to diagnose PJI is less accurate than the strict algorithmic calculation of the diagnosis as achieved in research. In fact, most physicians in this study would have improved their diagnostic accuracy for PJI by simply utilizing a single good test to make the diagnosis, instead of trying to combine multiple tests into a decision. We propose that less complex diagnostic criteria should be explored for routine clinical utilization.
Insights
Physicians using multiple criteria for periprosthetic joint infection (PJI) diagnosis showed high indecision and variability. Simpler diagnostic approaches are needed for better accuracy in clinical practice.
Area of Science:
- Orthopedic Surgery
- Infectious Diseases
- Diagnostic Accuracy
Background:
- Multiple-criterion scoring systems for periprosthetic joint infection (PJI) are effective in research settings.
- Clinical practice often deviates from strict diagnostic algorithms, potentially reducing the effectiveness of complex criteria.
- Physician interpretation and synthesis of multiple PJI diagnostic criteria have not been previously studied.
Purpose of the Study:
- To assess the diagnostic accuracy of physicians using multiple preoperative laboratory criteria for PJI.
- To compare physician diagnostic performance with individual laboratory tests for PJI.
- To evaluate physician indecision rates and interobserver agreement in PJI diagnosis.
Main Methods:
- Twelve physicians (4 academic arthroplasty surgeons, 4 community arthroplasty surgeons, 4 infectious disease specialists) evaluated 277 clinical vignettes.
- Physicians used their routine practices to diagnose PJI based on multiple preoperative laboratory criteria.
- Diagnostic accuracy was compared against the 2013 Musculoskeletal Infection Society (MSIS) gold standard and individual tests.
Main Results:
- Physicians exhibited high undecided diagnosis rates (23.5%) and poor interobserver agreement (kappa: 0.49-0.63).
- Mean physician accuracy (90.8%) was inferior to alpha-defensin tests and comparable to SF-WBC and SF-PMN%.
- Academic arthroplasty surgeons showed lower indecision rates and higher interobserver agreement than community surgeons or ID specialists.
Conclusions:
- The complexity of integrating multiple PJI diagnostic criteria leads to physician indecision and variability.
- Physician diagnostic accuracy using multiple criteria is often inferior to algorithmic approaches or single, well-performing tests.
- Development of less complex diagnostic criteria is recommended for routine clinical use in PJI diagnosis.
Related Concept Videos
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
Pneumonia III: Complications and Assessment
Urine Studies II: Urine Culture and Sensitivity Test
Receiver Operating Characteristic Plot
Acute Pyelonephritis II: Diagnostic Studies and Management