Related Experiment Video
Updated: Aug 21, 2025

Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
Published on: September 21, 2011
A Universal Eluent System for Method Scouting and Separation of Biotherapeutic Proteins by Ion-Exchange,
Alexander B Schwahn1, Julia Baek2, Shanhua Lin2
1Thermo Fisher Scientific, Reinach4153, Switzerland.
Abstract:
Characterization and quality control of biotherapeutic proteins commonly require the application of several orthogonal separation techniques in order to establish product identity and purity. Many of the techniques used rely on a buffered aqueous mobile phase system to maintain the native conformation of the protein and its variants. Optimal pH, buffer substance(s), and chromatography methods vary with each protein of interest and result in tedious method development for each new drug product. Linear controlled pH gradient systems from pH 5.6 to pH 10.2 has been shown to provide a global method for the separation of charge variants of monoclonal antibodies. This can be realized using two balanced zwitterionic buffer blends. The pH linearity of the resulting system, with a cation ion exchange column in place, can generate any pH value in this accessible pH range. This study expands the scope of this buffer system and demonstrates its application in conjunction with a quaternary HPLC pump for several analytical techniques: the pH optimization of salt gradient-based anion and cation exchange during method development, as well as performing pH gradient elution. In addition, the same universal buffers are used for hydrophobic interaction and size exclusion chromatography. This eluent system omits the need to prepare different buffers for each method and flushing of the HPLC system between method changes. The implementation of this concept is further demonstrated to allow an automated method scouting approach and selection of different methods that requires minimal manual intervention.
More Related Videos
10:08An Economical and Versatile High-Throughput Protein Purification System Using a Multi-Column Plate Adapter
Published on: May 21, 2021
09:57Separation of Bioactive Small Molecules, Peptides from Natural Sources and Proteins from Microbes by Preparative Isoelectric Focusing IEF Method
Published on: June 14, 2020
Related Concept Videos
Ion-Exchange Chromatography
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
High-Performance Liquid Chromatography: Elution Process
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Affinity Chromatography
Types Of Column Chromatography
Gel Filtration Chromatography
When the...