Conversion hip arthroplasty (CHA) for failed internal fixation of intertrochanteric fractures (FIF-ITF) yields successful mid-term results. However, long femoral stems increase complication risks, particularly intraoperative femur fractures, warranting cautious use.

Area of Science:

  • Orthopedic Surgery
  • Trauma Surgery
  • Arthroplasty

Background:

  • Failed internal fixation of intertrochanteric fractures (FIF-ITF) often necessitates conversion hip arthroplasty (CHA).
  • Standard and long femoral stems are utilized in CHA, with varying complication profiles.

Purpose of the Study:

  • To evaluate the clinical outcomes and complication rates of standard versus long femoral stems in conversion hip arthroplasty following FIF-ITF.

Main Methods:

  • Retrospective, multi-center study of 54 patients undergoing CHA after FIF-ITF.
  • Patients were divided into standard stem (n=20) and long stem (n=34) groups.
  • Clinical outcomes assessed via Harris hip score (HHS) and SF-36; complications were meticulously recorded.

Main Results:

  • Overall complication rate was 27.8%, with long stems showing a significantly higher risk (P=0.031).
  • Long stem group experienced increased operation time and blood loss (P<0.05).
  • Both groups demonstrated significant mid-term improvement in HHS and SF-36 scores without significant differences at final follow-up.

Conclusions:

  • Conversion hip arthroplasty provides successful mid-term clinical results for FIF-ITF.
  • Long femoral stems should be used cautiously due to a higher risk of complications, especially intraoperative femur fractures.