A Community-based Stress Management Program: Using Wearable Devices to Assess Whole Body Physiological Responses in Non-laboratory Settings
Published on: January 22, 2018
Variation in blood pressure and heart rate of radiological technologists in worktime tracked by a wearable device: A
Ryogo Minamimoto1, Yui Yamada1, Yasuharu Sugawara1
1Department of Radiology, Department of Radiology, National Center for Global Health and Medicine, Tokyo, Japan.
Abstract:
The aim of this preliminary study was to measure the systolic BP (SBP) and diastolic BP (DBP) and heart rate (HR) of radiological technologists by WD, and evaluate variation among individuals by worktime, day of the week, job, and workplace. Measurements were obtained using a wristwatch-type WD with optical measurement technology that can measure SBP and DBP every 10 minutes and HR every 30 minutes. SBP, DBP, and HR data obtained at baseline and during work time were combined with the hours of work, day of the week, job, and workplace recorded by the participants in 8 consecutive weeks. We calculated the mean, the ratio to baseline and coefficient of variation [CV(%)] for SBP, DBP, and HR. SBP, DBP, and HR values were significantly higher during work hours than at baseline (p<0.03). The ratio to baseline values ranged from 1.02 to 1.26 for SBP and from 1.07 to 1.30 for DBP. The ratio to baseline for SBP and DBP showed CV(%) of approximately 10% according to the day of the week and over the study period. For HR, ratio to baseline ranged from 0.95 to 1.29. The ratio of mean BP to baseline was >1.2 at the time of starting work, middle and after lunch, and at 14:00. The ratio to baseline of SBP were 1.2 or more for irradiation, equipment accuracy control, registration of patient data, dose verification and conference time, and were also working in CT examination room, treatment planning room, linac room, and the office. CV(%) of BP and HR were generally stable for all workplaces. WD measurements of SBP, DBP, and HR were higher during working hours than at baseline and varied by the individuals, work time, job, and workplace. This method may enable evaluation of unconscious workload in individuals.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Errors occurring during blood pressure monitoring
Several factors...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Holter Monitor: 24-Hour Monitoring