Experimental feasibility of xenon-enhanced dual-energy radiography for imaging of lung function
Fateen Basharat1, Jesse Tanguay1
1Department of Physics, Toronto Metropolitan University, Toronto, ON, Canada.
Abstract:
Chronic obstructive pulmonary disease (COPD) is a leading cause of death worldwide. We experimentally investigated the feasibility of two-dimensional xenon-enhanced dual-energy (XeDE) radiography for imaging of lung function. We optimized image quality under quantum-noise-limited conditions using a chest phantom consisting of a rectangular chamber representing the thoracic volume and PMMA slabs simulating x-ray attenuation by soft tissue. A sealed, air-filled cavity with thin PMMA walls was positioned inside the chamber to simulate a 2 cm thick ventilation defect. The chamber was ventilated with xenon and dual-energy imaging was performed using a diagnostic x-ray tube and a flat-panel detector. The contrast-to-noise ratio of ventilation defects normalized by patient x-ray exposure maximized at a kV-pair of approximately 60/140-kV and when approximately one third of the total exposure was allocated to the HE image. We used the optimized technique to image a second phantom that contained lung-parenchyma-mimicking PMMA clutter, rib-mimicking aluminum slats and an insert that simulated ventilation defects with thicknesses ranging from 0.5 cm to 2 cm and diameters ranging from 1 cm to 2 cm. From the resulting images we computed the area under the receiver operating characteristic curve (AUC) of the non-prewhitening model observer with an eye filter and internal noise. For a xenon concentration of 75%, good AUCs (i.e. 0.8-0.9) to excellent AUCs (i.e. >0.9) were obtained when the defect diameter is greater than 1.3 cm and defect thickness is 1 cm. When the xenon concentration was reduced to 50%, the AUC was ∼0.9 for defects 1.2 cm in diameter and ∼1.5 cm in thickness. Two-dimensional XeDE radiography may therefore enable detection of functional abnormalities associated with early-stage COPD, for which xenon ventilation defects can occupy up to 20% of the lung volume, and should be further developed as a low-cost alternative to MRI-based approaches and a low-dose alternative to CT-based approaches.
Related Concept Videos
X-ray Imaging
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET