Related Experiment Video
Updated: Aug 20, 2025

How to Administer Near-Infrared Spectroscopy in Critically ill Neonates, Infants, and Children
Published on: August 19, 2020
Evaluating enhanced pulse oximetry auditory displays for neonatal oxygen targeting: A randomized laboratory trial
Kelly Hinckfuss1, Penelope M Sanderson2, Birgit Brecknell1
1School of Psychology, The University of Queensland, Brisbane, Australia.
Abstract:
Standard pulse oximeter auditory tones do not clearly indicate departures from the target range of oxygen saturation (SpO2) of 90%-95% in preterm neonates. We tested whether acoustically enhanced tones would improve participants' ability to identify SpO2 range. Twenty-one clinicians and 23 non-clinicians used (1) standard pulse oximetry variable-pitch tones plus alarms; (2) beacon-enhanced tones without alarms in which reference tones were inserted before standard pulse tones when SpO2 was outside target range; and (3) tremolo-enhanced tones without alarms in which pulse tones were modified with tremolo when SpO2 was outside target range. For clinicians, range identification accuracies (mean (SD)) in the standard, beacon, and tremolo conditions were 52% (16%), 73% (14%) and 76% (13%) respectively, and for non-clinicians 49% (16%), 76% (13%) and 72% (14%) respectively, with enhanced conditions always significantly more accurate than standard. Acoustic enhancements to pulse oximetry clearly indicate departures from preterm neonates' target SpO2 range.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
06:57Use of an Integrated Low-Flow Anesthetic Vaporizer, Ventilator, and Physiological Monitoring System for Rodents
Published on: July 9, 2020
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...