Related Experiment Video
Updated: Aug 20, 2025

Author Spotlight: Automated Lifespan Monitoring – Discovering Aging Dynamics with the Lifespan Machine
Published on: January 26, 2024
Long term WEB results - still going strong at 5 years?
Kemal Alpay1, Alberto Nania2, Rahul Raj3
1Department of Radiology, Turku University Hospital, Turku, Finland.
The Woven EndoBridge (WEB) device shows acceptable 5-year occlusion rates for intracranial aneurysms. Recanalization is unlikely after two years, suggesting promising long-term outcomes for this minimally invasive treatment.
Area of Science:
- Neuroendovascular
- Neurosurgery
- Radiology
Background:
- Intracranial aneurysms (IAs) pose significant risks.
- Endovascular treatments are evolving for IA management.
- The Woven EndoBridge (WEB) device is a notable option.
Purpose of the Study:
- To evaluate the 5-year radiological outcomes of IAs treated with the WEB device.
- To assess the long-term efficacy and safety of WEB embolization.
Main Methods:
- Multi-center retrospective study.
- Inclusion of patients treated with WEB from January 2013 to December 2016.
- Assessment of aneurysm occlusion using a 3-grade scale at 5-year follow-up.
Main Results:
- 83.7% of treated IAs achieved adequate occlusion at 5 years.
- Complete occlusion was observed in 47.3% of cases.
- Recanalization occurred in 16.3% of IAs, with no rebleeding events reported.
Conclusions:
- The WEB device demonstrates acceptable long-term occlusion rates for intracranial aneurysms.
- Recanalization is infrequent after the initial two years post-treatment.
- Further large-scale studies are warranted to confirm these findings.