Related Experiment Video
Updated: Aug 20, 2025

Detection and Removal of Tooth-Colored Composite Resin Using the Fluorescence-Aided Identification Technique
Published on: July 27, 2022
Evaluation of direct restorations using the revised FDI criteria: results from a reliability study
Sabine Mesinger1, Katrin Heck1, Alexander Crispin2
1Department of Conservative Dentistry and Periodontology, University Hospital, Ludwig Maximilians-University of Munich, Goethestraße 70, 80336, Munich, Germany.
Objectives:
The purpose of this in vitro reliability study was to determine the intra- and inter-examiner agreement of the revised FDI criteria including the categories "fracture of material and retention" (F1) and "caries at restoration margin" (B1).
Materials And Methods:
Forty-nine photographs of direct tooth-coloured posterior (n = 25) and anterior (n = 24) restorations with common deficiencies were included. Ten dental experts repeated the assessment in three blinded rounds. Later, the experts re-evaluated together all photographs and agreed on a reference standard. Statistical analysis included the calculation of Cohen's (Cκ), Fleiss' (Fκ), and weighted Kappa (wκ), the development of a logistic regression with a backward elimination model and Bland/Altman plots.
Results:
Intra- and inter-examiner reliability exhibited mostly moderate to substantial Cκ, Fκ, and wκ values for posterior restorations (e.g. Intra: F1 Cκ = 0.57, wκ = 0.74; B1 Cκ = 0.57, wκ = 0.73/Inter F1 Fκ = 0.32, wκ = 0.53; B1 Fκ = 0.41, wκ = 0.64) and anterior restorations (e.g. Intra F1 Cκ = 0.63, wκ = 0.76; B1 Cκ = 0.48, wκ = 0.68/Inter F1 Fκ = 0.42, wκ = 0.57; B1 Fκ = 0.40, wκ = 0.51). Logistic regression analyses revealed significant differences between the evaluation rounds, examiners, categories, and tooth type. Both the intra- and inter-examiner reliability increased along with the evaluation rounds. The overall agreement was higher for anterior restorations compared to posterior restorations.
Conclusions:
The overall reliability of the revised FDI criteria set was found to be moderate to substantial.
Clinical Relevance:
If properly trained, the revised FDI criteria set are a valid tool to evaluate direct and indirect restorations in a standardized way. However, training and calibration are needed to ensure reliable application.
More Related Videos
10:42A Postoperative Evaluation Guideline for Computer-Assisted Reconstruction of the Mandible
Published on: January 28, 2020
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024