Related Experiment Video
Updated: Aug 20, 2025

Assessment and Evaluation of the High Risk Neonate: The NICU Network Neurobehavioral Scale
Published on: August 25, 2014
Autonomic markers of extubation readiness in premature infants
Suma B Hoffman1,2, Rathinaswamy B Govindan3,4, Elena K Johnston5
1Division of Neonatology, Children's National Hospital, Washington, DC, USA. sbhoffman@childrensnational.org.
Background:
In premature infants, extubation failure is common and difficult to predict. Heart rate variability (HRV) is a marker of autonomic tone. Our aim is to test the hypothesis that autonomic impairment is associated with extubation readiness.
Methods:
Retrospective study of 89 infants <28 weeks. HRV metrics 24 h prior to extubation were compared for those with and without extubation success within 72 h. Receiver-operating curve analysis was conducted to determine the predictive ability of each metric, and a predictive model was created.
Results:
Seventy-three percent were successfully extubated. The success group had significantly lower oxygen requirement, higher sympathetic HRV metrics, and a lower parasympathetic HRV metric. α1 (measure of autocorrelation, related to sympathetic tone) was the best predictor of success-area under the curve (AUC) of .73 (p = 0.001), and incorporated into a predictive model had an AUC of 0.81 (p < 0.0001)-sensitivity of 81% and specificity of 78%.
Conclusions:
Extubation success is associated with HRV. We show an autonomic imbalance with low sympathetic and elevated parasympathetic tone in those who failed. α1, a marker of sympathetic tone, was noted to be the best predictor of extubation success especially when incorporated into a clinical model.
Impact:
This article depicts autonomic markers predictive of extubation success. We depict an autonomic imbalance in those who fail extubation with heightened parasympathetic and blunted sympathetic signal. We describe a predictive model for extubation success with a sensitivity of 81% and specificity of 78%.
Related Concept Videos
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.