Variability of microcirculatory measurements in healthy volunteers

M E Bol1,2, B E K Broddin3, T Delhaas4

  • 1Department of Intensive Care Medicine, Maastricht University Medical Center, MUMC+), Maastricht, The Netherlands. martine.bol@mumc.nl.

Scientific Reports
|November 18, 2022
PubMed

Reliable assessment of the microcirculation is important to investigate microcirculatory properties in various disease states. The GlycoCheck system automatically analyzes sublingual sidestream dark field images to determine the perfused boundary region (PBR; a measure of glycocalyx thickness), red blood cell filling percentage, and microvascular vessel density. Although GlycoCheck has been used to study the microcirculation in patients, little is known about the reproducibility of measurements in healthy volunteers. We assessed intra- and interobserver agreement by having two experienced observers perform three consecutive microcirculation measurements with the GlycoCheck system in 49 healthy volunteers. Intraobserver agreement of single measurements were poor (intraclass correlation coefficients (ICCs) < 0.4) for PBR, red blood cell filling percentage and microvascular vessel density. ICCs increased to values > 0.6 (indicating good reproducibility) for all parameters when performing and averaging three consecutive measurements. No systematic differences were observed between observers for any parameter. Interobserver variability was fair for PBR (ICC = 0.53) and red blood cell filling percentage (ICC = 0.58) and poor for perfused vessel density (ICC = 0.20). In conclusion, GlycoCheck software can be used with acceptable reliability and reproducibility for microcirculation measurements on a population level when averaging three consecutive measurements. Repeated measurements are preferably performed by the same observer.

Related Concept Videos

Measurement of Blood Pressure01:17

Measurement of Blood Pressure

Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a...
1.2K
Variability: Analysis01:11

Variability: Analysis

Measures of variability are statistical metrics that reveal the dispersion pattern within a dataset. They are pivotal in biostatistics, providing insights into the heterogeneity within health and biological data. Variability signifies the degree to which data points diverge from one another, helping researchers understand the potential range of values and associated uncertainty within the data.
The range is a simple measure of variability, indicating the difference between the highest and...
177
Autoregulation of Blood Flow01:17

Autoregulation of Blood Flow

Autoregulation mechanisms are characterized by their inherent capacity for self-regulation without necessitating specific nervous stimulation or endocrine control. These mechanisms facilitate the adjustment of blood flow and, therefore, perfusion specific to each tissue region. This self-regulation encompasses chemical signals and myogenic controls.
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation....
2.6K