Monitoring indoor air quality using smart integrated gas sensor module (IGSM) for improving health in COPD patients
Bethanney Janney John1, Chandana Harish1, Caroline Chriselda Lawrence1
1Department of Biomedical Engineering, Sathyabama Institute of Science and Technology, Chennai, Tamil Nadu, India, 600119.
Abstract:
Technology advancement, industrialisation, and globalisation have been significant reasons for air pollution outdoors and indoors. It may surprise us that we spend about 80% of our time indoors breathing toxic, stale, polluted air, making us sluggish and fretful. In contrast to outdoor air, indoor air does not recycle consistently. It traps and builds pollutants from wood and coal stoves, furniture and building materials, paints and solvents, cigarette smoke, and cleaning supplies. The prolonged exposure to these hidden pollutants can prompt respiratory disorders such as lung disease, pneumonitis, asthma, pulmonary hypertension, and chronic obstructive pulmonary disease (COPD). It is enduring and is not curable, which has been a threat to humanity for ages. COPD's major cause is airborne particulate matter and other toxic compounds emitted from indoor and outdoor sources. Outdoor air pollution can be controlled only by acquiring changes in the vast population, wherein for indoor, every individual may create a major impact on improving air purity, thereby promoting health. The proposed design model for monitoring indoor air quality was tested in a normal and stimulating environment where we live. Parameters tested included temperature, humidity, amount of PM2.5, and the concentration of CO, CO2, and NH3. These parameters were monitored for five to 6 h per day for 8 days. Results indicate that the total air quality lies in the moderate range. Further study will be helpful to utilise this module as an effective Indoor air quality (IAQ) monitoring system. HIGHLIGHTS: • A simple, effective, inexpensive integrated gas sensor module (IGSM) has been proposed in this study to monitor the indoor air quality index (IAQI). • Indoor air quality was tested in a normal and stimulating environment for 8 days. • The integrated gas sensor module (IGSM) was composed of sensors in series, and the outputs for the respective parameter were measured easily. • Among the parameters tested, CO and PM2.5 lie in the moderate range, while other pollutants within the normal range reveal that the tested air quality is moderate.
More Related Videos
Related Concept Videos
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Chronic Obstructive Pulmonary Disease-I: Introduction
COPD: Management Using Bronchodilators and Corticosteroids
Chronic Obstructive Pulmonary Disease-V: Nursing Management
Assessment
Chronic Obstructive Pulmonary Disease-V: Management
Smoking Cessation
Chronic Obstructive Pulmonary Disease
Smoking is a primary risk factor for COPD, with over 80% of patients having a history of it. Patients typically experience progressive dyspnea or labored breathing, frequent coughing, and recurrent pulmonary infections. Many eventually succumb to respiratory failure, characterized by...


