Related Experiment Video
Updated: Aug 20, 2025

Quantification of Levator Ani Hiatus Enlargement by Magnetic Resonance Imaging in Males and Females with Pelvic Organ Prolapse
Published on: April 17, 2019
Video-Based Deep Learning to Detect Dyssynergic Defecation with 3D High-Definition Anorectal Manometry
Joshua J Levy1,2,3,4, Christopher M Navas1, Joan A Chandra1
1Section of Gastroenterology and Hepatology, Dartmouth-Hitchcock Health, One Medical Center Drive, Lebanon, NH, 03756, USA.
Background:
We developed a deep learning algorithm to evaluate defecatory patterns to identify dyssynergic defecation using 3-dimensional high definition anal manometry (3D-HDAM).
Aims:
We developed a 3D-HDAM deep learning algorithm to evaluate for dyssynergia.
Methods:
Spatial-temporal data were extracted from consecutive 3D-HDAM studies performed between 2018 and 2020 at Dartmouth-Hitchcock Health. The technical procedure and gold standard definition of dyssynergia were based on the London consensus, adapted to the needs of 3D-HDAM technology. Three machine learning models were generated: (1) traditional machine learning informed by conventional anorectal function metrics, (2) deep learning, and (3) a hybrid approach. Diagnostic accuracy was evaluated using bootstrap sampling to calculate area-under-the-curve (AUC). To evaluate overfitting, models were validated by adding 502 simulated defecation maneuvers with diagnostic ambiguity.
Results:
302 3D-HDAM studies representing 1208 simulated defecation maneuvers were included (average age 55.2 years; 80.5% women). The deep learning model had comparable diagnostic accuracy [AUC 0.91 (95% confidence interval 0.89-0.93)] to traditional [AUC 0.93(0.92-0.95)] and hybrid [AUC 0.96(0.94-0.97)] predictive models in training cohorts. However, the deep learning model handled ambiguous tests more cautiously than other models; the deep learning model was more likely to designate an ambiguous test as inconclusive [odds ratio 4.21(2.78-6.38)] versus traditional/hybrid approaches.
Conclusions:
Deep learning is capable of considering complex spatial-temporal information on 3D-HDAM technology. Future studies are needed to evaluate the clinical context of these preliminary findings.
More Related Videos
07:41Video Imaging and Spatiotemporal Maps to Analyze Gastrointestinal Motility in Mice
Published on: February 3, 2016
06:36A Decentralized Ex Vivo Murine Bladder Model with the Detrusor Muscle Removed for Direct Access to the Suburothelium during Bladder Filling
Published on: November 28, 2019
Related Concept Videos
Assessment of the Rectum and Anus
Rectal Inspection
Begin by inspecting the perianal and anal areas for color, texture, rashes,...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Imaging Studies VI: Voiding Cystourethrography and Cystography