Related Experiment Video
Updated: Aug 20, 2025

Adjustable Stiffness, External Fixator for the Rat Femur Osteotomy and Segmental Bone Defect Models
Published on: October 9, 2014
Locking the Taylor Spatial Frame - The effect of three additional longitudinal rods on osteotomy site movements
Sebastian Lotzien1, Thomas Rosteius1, Birger Jettkant1
1Department of General and Trauma Surgery, BG University Hospital Bergmannsheil, Bürkle- de-la-Camp Platz 1, 44789 Bochum, Germany.
Background:
In clinical practice, even when the fixator is locked, a noticeable laxity of the construct can be observed. This study was designed to measure the stiffness of the fixator and to analyze the movements of the osteotomy site. Furthermore, the effect of three additional longitudinal rods on the locking of the construct was analyzed.
Methods:
Five synthetic tibia/fixator models (Model A) were tested under rotational torque (40 Nm) and axial compression (700 N). Three additional rigid rods were subsequently mounted, and the tests were repeated (Model B). The movements of the fixator as well as the osteotomy site were registered by a digital optical measurement system. Load- deformation curves, and so stiffness of the models, were calculated and compared.
Findings:
Under rotational and axial loadings, Model A was found to be less rigid than Model B (p = 0.034; p = 0.194). Notably, Model A showed a region of laxity around neutral rotational (ΔF = 5 Nm) and axial (ΔF = 16.64 N) loading before a linear deformation trend was measured. Concomitantly, greater osteotomy site movement was measured for Model A than for Model B under full loading (p = 0.05) and within the region of increased laxity (p = 0.042).
Interpretation:
The fixator showed an element of laxity around neutral axial and rotational loading, which transferred to the bone and led to a notable amount of osteotomy gap movement. Mounting three additional rods increased the stiffness of the construct and therefore reduced the movement of the osteotomy site.
More Related Videos
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
07:35Creating Rigidly Stabilized Fractures for Assessing Intramembranous Ossification, Distraction Osteogenesis, or Healing of Critical Sized Defects
Published on: April 11, 2012
Related Concept Videos
Stability of structures
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...
Temperature Dependent Deformation
Space Trusses: Problem Solving
Consider a tripod consisting of a tetrahedral space truss with a ball-and-socket joint at C. Suppose the height and lengths of the horizontal and vertical...
Eccentric Axial Loading in a Plane of Symmetry