Related Experiment Video
Updated: Aug 20, 2025

Digital Home-Monitoring of Patients after Kidney Transplantation: The MACCS Platform
Published on: April 12, 2021
Effects of body parameters on renal cortical stiffness measured by shear-wave elastography in patients with kidney
Shuting Yang1, Yuwan Liu2, Huilan Zuo3
1Department of Ultrasonography, Third Xiangya Hospital, Central South University, Changsha 410013. yangshutingsm@163.com.
Objectives:
The results of elastic imaging in evaluating the function and histopathological changes of allogeneic renal transplantation are contradictory, one of the important reasons may be that there are differences in human parameters related to kidney transplantation among individuals. The purpose of this study is to explore the related human body parameters on shear-wave elastography (SWE) effects on quantitative stiffness of graft cortex.
Methods:
From March 2021 to November 2021, a total of 63 patients with allogeneic kidney transplantation in the Department of Ultrasonography, Third Xiangya Hospital, Central South University, were selected to collect the parameters of two-dimensional, color Doppler and SWE. The subjects were divided into a <20% group and a 20%-30% group according to the variation of cortical hardness measurement. Mann Whitney U test was used to compare the differences in relevant human parameters, and Spearman rank correlation was used to analyze the correlation between relevant human parameters and cortical hardness of transplanted kidney.
Results:
There was no significant difference between the 2 groups in age, sex, postoperative time, resistance index of interlobar artery, SCr, blood uric acid, ratio of fat layer to muscle layer, and BMI (all P>0.05). Compared with the <20% group, the patients in the 20%-30% group had smaller cortical hardness of the transplanted kidney, greater total distance between the transplanted kidney and the skin surface, and thicker fat layer or muscle layer in front of the transplanted kidney (all P<0.05). The age of patients, the total distance from the transplanted kidney to the skin surface, the thickness of fat layer and muscle layer, the ratio of fat layer to muscle layer, BMI, and the variation of cortical hardness were significantly negatively correlated with the cortical hardness of the transplanted kidney (all P<0.05).
Conclusions:
Human parameters relevant to kidney transplantation affect the accuracy of SWE in measuring the cortical hardness of the transplanted kidney. It is very important to obtain the highly stabile elastic measurement value and interpret the elastic measurement results according to different levels of human body related parameters in combination with individual conditions.
Related Concept Videos
Kidney Transplant I: Introduction
Kidney Transplant III: Nursing Management
Kidney Transplant II: Surgical Procedure
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
Renal Failure: Dose Adjustments
Reduced renal clearance and elimination rate are common outcomes of renal impairment. These alterations lead to a prolonged elimination half-life and an altered apparent volume of distribution for drugs. As a result, dosage adjustments are typically necessary to maintain optimal drug levels in the body.
However, dosage adjustments...
Acute Kidney Injury IV: Diagnostic Studies and Prevention

