Related Experiment Video
Updated: Aug 20, 2025

Author Spotlight: Demonstrating Systematic Endobronchial Ultrasound to New Endoscopists
Published on: August 11, 2023
Assessment of Tissue Adequacy by EBUS in Conjunction with PET Scan and Operator's Experience
Nagla Abdel Karim1, Asad Ullah2, Steven Pulliam3
1Inova Schar Cancer Institute, University of Virginia, Fairfax, VA 22031, USA.
Abstract:
Mediastinal lymph node assessment is a crucial step in non-small cell lung cancer staging. Positron emission tomography (PET) has been the gold standard for the assessment of mediastinal lymphadenopathy, though it has limited specificity. Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is quick, accurate, and a less invasive method for obtaining a diagnostic sample in contrast to mediastinoscopy. We performed a retrospective chart analysis of 171 patients to assess the adequacy of tissue obtained by EBUS for diagnosis and molecular profiling as well as the assessment of staging and lymph node (LN) stations diagnostic yield, in correlation to PET scan and the operator’s level of experience. A significantly increased tissue adequacy was observed based on the operators’ experience, with the highest adequacy noted in trained Interventional Pulmonologist (IP) (100%), followed by >5 years of experience (93.33%), and 88.89% adequacy with <5 years of experience (p = 0.0019). PET-CT scan 18F-fluorodeoxyglucose (FDG) uptake in levels 1, 2, and 3 LN had a tissue adequacy of 76.67%, 54.64%, and 35.56%, respectively (p = 0.0009). EBUS bronchoscopy method could be used to achieve an accurate diagnosis, with IP-trained operators yielding the best results. There is no correlation with PET scan positivity, indicating that both PET and EBUS are complementary methods needed for staging.
More Related Videos
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):

