Association Between Pressure Support During Extubation Readiness Testing and Time to First Extubation in Children
Andrew G Miller1, Karan R Kumar2, Jessica Brown2
1Duke University Medical Center, Durham, North Carolina. Andrew.g.miller@duke.edu.
Background:
Extubation readiness testing (ERT) is often performed in children with congenital heart disease prior to liberation from mechanical ventilation. The ideal ERT method in this population is unknown. We recently changed our ERT method from variable (10, 8, or 6 cm H2O, depending on endotracheal tube size) to fixed (5 cm H2O) pressure support (PS). Our study assessed the association between this change and time to first extubation and need for re-intubation.
Methods:
We studied 2 temporally distinct cohorts, one where ERT was conducted with variable PS and another using PS fixed at 5 cm H2O. Data were prospectively collected as part of a quality improvement project. The primary outcome was time to first extubation. Secondary outcomes were need for re-intubation and percentage of successful ERTs. We performed Poisson regression or logistic regression for the association between PS during ERT and time to first extubation or re-intubation, respectively.
Results:
We included 320 subjects, 186 in the variable PS group and 152 in fixed PS group. In unadjusted analysis, median time to first extubation was longer in the fixed PS group compared to the variable PS group (4.1 [2.0-7.1] d vs 3.1 [1.1-5.9] d, P = .02), and there was no difference in re-intubation rate (11% vs 8%, P = .34). Subjects in the fixed PS group were significantly more likely to be mechanically ventilated after cardiac arrest, have a Society of Thoracic Surgeons-European Association for Cardio-Thoracic Surgery (STAT) category of 4 or 5, be extubated on day shift, receive enteral feeds at extubation, have higher respiratory support at extubation, and higher dead-space-to-tidal-volume ratio. After controlling for these variables in multivariable regression, we found no association between the choice of PS and time to first extubation or re-intubation.
Conclusions:
The use of a fixed PS of 5 cm H2O instead of variable PS during ERT was not associated with longer time to first extubation or extubation failure.
Related Concept Videos
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Cardiopulmonary Resuscitation II: ACLS Airway Management