Related Experiment Video
Updated: Aug 20, 2025

Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
Quantitative Assessment of Computed Tomography Energy Use and Cost Savings Through Overnight and Weekend Power Down
Maura Brown1, Eric Snelling2, Moises De Alba3
1Department of Radiology, UBC Faculty of Medicine, Vancouver, BC, Canada; BC Cancer Planetary Health Unit, Diagnostic Imaging, 8144BC Cancer, Vancouver, BC, Canada.
Abstract:
Purpose: To assess energy and cost savings when a CT scanner is powered down during overnight non-operational times compared with the CT scanner left on full power or partial shutdown mode. Materials and Methods: Temporary portable power data loggers were placed on the power supply to the CT scanner to measure the energy consumption of the CT scanner in 3 power modes over 9 weeks: system ON (computer on, gantry on), computer ON (computer on/gantry off), and system shutdown (computer off/gantry off). Energy was separated into daily average consumption during normal operating hours and consumption after hours for three different day types: weekdays, Saturdays, and Sundays/Holidays. To estimate savings, the average after hours energy use per day during the system ON was compared to each of the two power saving modes. 95% confidence intervals were calculated for each mode and savings result. Results: Overnight and Sunday system shutdown compared to system ON mode is shown to save approximately 14 000 kWh over one year with a 95% confidence interval of (13 899 kWh, 14 464 kWh) as calculated by the electricity provider. Conclusion: Energy consumed by a CT scanner can be significantly reduced through system shutdown when the unit is non-operational, saving emissions and cost. In addition to cost and energy savings, this study emphasizes the importance of clinician leadership in convening interdisciplinary teams outside of usual healthcare silos to rethink how we purposefully use energy and reduce waste.
More Related Videos
05:32Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph
Published on: February 21, 2025
09:21Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images
Published on: February 18, 2015
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT