Related Experiment Video
Updated: Aug 20, 2025

Quantification of Metal Leaching in Immobilized Metal Affinity Chromatography
Published on: January 17, 2020
Cr(III) Ion-Imprinted Hydrogel Membrane for Chromium Speciation Analysis in Water Samples
Ivanka Dakova1, Penka Vasileva1, Irina Karadjova1
1Faculty of Chemistry and Pharmacy, University of Sofia "St. Kliment Ohridski", 1, J. Bourchier Blvd., 1164 Sofia, Bulgaria.
Abstract:
Novel Cr(III)-imprinted poly(vinyl alcohol)/sodium alginate/AuNPs hydrogel membranes (Cr(III)-IIMs) were obtained and characterized and further applied as a sorbent for chromium speciation in waters. Cr(III)-IIMs were prepared via solution blending method using blends of poly(vinyl alcohol) and sodium alginate as film-forming materials, poly(ethylene glycol) as a porogen agent, sodium alginate stabilized gold nanoparticles (SA-AuNPs) as a crosslinking and mechanically stabilizing component, and Cr(III) ions as a template species. The physicochemical characteristics of pre-synthesized AuNPs and obtained hydrogel membranes Cr(III)-IIM were studied by UV-vis and FTIR spectroscopy, TEM and SEM observations, N2 adsorption-desorption measurements, and XRD analysis. The mechanism of the adsorption process toward Cr(III) was best described by pseudo-first-order kinetic and Langmuir models. Experiments performed showed that quantitative retention of Cr(III) is attained in 20 h at pH 6 and temperature 40 °C. Under the same conditions, the adsorption of Cr(VI) is below 5%. A simple and sensitive analytical procedure was developed for the speciation of Cr in an aquatic environment using dispersive solid phase extraction of Cr(III) by Cr(III)-IIM prior to selective Cr(VI) measurement by ETAAS in the supernatants. The detection limits and reproducibility achieved for the Cr speciation analysis fulfill the requirements for their monitoring in waters under the demand of the Water Framework Directive.
More Related Videos
09:42Fabrication of a Dipole-assisted Solid Phase Extraction Microchip for Trace Metal Analysis in Water Samples
Published on: August 7, 2016
07:54Analysis of AtHIRD11 Intrinsic Disorder and Binding Towards Metal Ions by Capillary Gel Electrophoresis and Affinity Capillary Electrophoresis
Published on: August 22, 2018
Related Concept Videos
Ion-Exchange Chromatography
High-Performance Liquid Chromatography: Elution Process
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...