Related Experiment Video
Updated: Aug 20, 2025

Oxygenation-sensitive Cardiac MRI with Vasoactive Breathing Maneuvers for the Non-invasive Assessment of Coronary Microvascular Dysfunction
Published on: August 17, 2022
Quantification of the Tissue Oxygenation Delay Induced by Breath-Holding in Patients with Carotid Atherosclerosis
Andrés Quiroga1, Sergio Novi1, Giovani Martins1,2
1"Gleb Wataghin" Institute of Physics, University of Campinas, Campinas 13083-859, SP, Brazil.
Insights
Carotid artery stenosis (CAS) impairs brain blood flow, with severe cases showing delayed hemodynamic responses. This study introduces a new method using functional near-infrared spectroscopy (fNIRS) to quantify these delays in CAS patients.
Area of Science:
- Neuroscience
- Vascular Biology
- Medical Imaging
Background:
- Carotid artery stenosis (CAS) is a prevalent vascular condition linked to brain damage.
- Impaired cerebral hemodynamics in the microvasculature of CAS patients are not well understood.
- Understanding these hemodynamic changes is crucial for managing neurological consequences.
Purpose of the Study:
- To introduce and validate a novel methodological approach for quantifying temporal delays in evoked hemodynamic responses.
- To assess cerebral hemodynamic impairment in patients with carotid artery stenosis (CAS) using functional near-infrared spectroscopy (fNIRS).
Main Methods:
- Functional near-infrared spectroscopy (fNIRS) was utilized to measure hemodynamic responses.
- A vasodilatory task (breath-holding) was employed to evoke a measurable hemodynamic response.
- The methodology was validated in 50 CAS patients and 20 healthy controls.
Main Results:
- A significant delay in the hemodynamic response to breath-holding was observed in severe CAS patients (up to 6s) compared to controls (median 4s).
- The proportion of brain regions responding to the task decreased with increasing CAS severity (90% in controls to 73% in severe CAS).
- Collateral circulation improved the response but did not fully normalize time delays; artery count alone was not predictive.
Conclusions:
- A new quantitative method using fNIRS can effectively assess impaired cerebral hemodynamics in CAS patients.
- The findings highlight significant hemodynamic alterations in the brain microvasculature due to CAS.
- This method offers potential for improved diagnosis and monitoring of neurological complications in CAS.
Abstract:
Carotid artery stenosis (CAS) is a common vascular disease with long-term consequences for the brain. Although CAS is strongly associated with impaired cerebral hemodynamics and neurodegeneration, the mechanisms underlying hemodynamic impairment in the microvasculature remain unknown. In this work, we employed functional near-infrared spectroscopy (fNIRS) to introduce a methodological approach for quantifying the temporal delay of the evoked hemodynamic response. The method was validated during a vasodilatory task (breath-holding) in 50 CAS patients and 20 controls. Our results suggest that the hemodynamic response to breath-holding can be delayed by up to 6 s in the most severe patients, a significant increase from the median 4 s measured for the control group (p = 0.01). In addition, the fraction of brain regions that responded to the task decreased as the CAS severity increased, from a median of 90% in controls to 73% in the most severe CAS group (p = 0.04). The presence of collateral circulation increases the response to breath-holding and decreases the average time delays across the brain, although the number of communicating arteries alone cannot predict these fNIRS-based hemodynamic variables (p > 0.09). Overall, this work proposes a method to quantitatively assess impaired cerebral hemodynamics in CAS patients.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...