Related Experiment Video
Updated: Aug 20, 2025

Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
Subject-wise model generalization through pooling and patching for regression: Application on non-invasive systolic
Hazem Mohammed1, Kai Wang2, Hao Wu3
1Department of Micro/Nano Electronics, School of Electrical, Information, and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, China; Electrical Engineering Department, Faculty of Engineering, Assuit University, Asyut, Egypt.
Background:
Subject-wise modeling using machine learning is useful in many applications requiring low error and complexity, such as wearable medical devices. However, regression accuracy depends highly on the data available to train the model and the model's generalization ability. Adversely, the prediction error may increase severely if unknown data patterns test the model; such a model is known to be overfitted. In medicine-related applications, such as Non-Invasive Blood Pressure (NIBP) estimation, the high error renders the estimation model useless and dangerous.
Methods:
This paper presents a novel algorithm to handle overfitting by editing the training data to achieve generalization for subject-wise models. The pooling and patching (PaP) algorithms use a relatively short record segment of a subject as a Key-Segment (KS) to search through a larger dataset for similar subjects. Then samples taken from the matched subjects' pool records are used to patch the original subject's KS. Due to the significance of systolic blood pressure (SBP) and the complexity of its variability, non-invasive estimation of SBP from electrocardiography (ECG) and photoplethysmography (PPG) is introduced as an application to assess the algorithm. The study was performed on 2051 subjects with a wide range of age, height, weight, length, and health status. The subjects' records were taken from a large public dataset, VitalDB, which is acquired from subjects undergoing different surgeries. Finally, all the results are obtained without using other model generalization techniques.
Results:
The generalization effect of the proposed algorithm, PaP, significantly outperformed cross-validation, which is widely used in regression model generalization. Moreover, the testing results show that a KS of 200 to 2000 samples is sufficient for providing high accuracy for much longer testing data of about 12000 to 24000 samples long, which is less than %10 of the record length on average. Furthermore, compared to other works based on the same dataset, PaP provides a significantly lower mean error of -0.75 ± 5.51 mmHg, with a small training data portion of 15% over 2051 subjects.
More Related Videos
Related Concept Videos
Measurement of Blood Pressure
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...