Related Experiment Video
Updated: Aug 20, 2025

Author Spotlight: Enhancing Diagnostic Strategies and Biomarker Development for Comprehensive Lung Function Analysis
Published on: August 9, 2024
Evaluation of lung perfusion by using lung perfusion SPECT and lung CT with breathing synchronization software
Hidenobu Hashimoto1, Tsutomu Soma2, Sunao Mizumura3
1Department of Cardiovascular Medicine, Department of Internal Medicine, Faculty of Medicine, Toho University, 6-11-1, Omorinishi, Ota-Ward, Tokyo, 143-8541, Japan. hidenobu.hashimoto@med.toho-u.ac.jp.
Background:
Lung perfusion using 99mTc-macroaggregated albumin single-photon emission computed tomography (SPECT) and lung computed tomography (CT) is a useful modality for identifying patients with pulmonary artery embolism. However, conformity between SPECT and CT at the bottom of the lung is generally low. This study aims to investigate the progression of conformity between lung perfusion SPECT and lung CT using a breathing synchronization software.
Methods:
Among 95 consecutive patients who underwent lung perfusion SPECT and lung CT within 14 days because of suspected pulmonary embolism between June 2019 and August 2020 in department of cardiovascular medicine, we identified 28 patients (73 ± 10 years) who had normal pulmonary artery on contrast lung CT. We compared lung volumes calculated using lung perfusion SPECT and lung CT as gold standard. Visual conformity between lung SPECT and lung CT was scored 0-4 (0: 0-25%, 1: 25-50%, 2: 50-75%, 3: 75-90%, 4: > 90%) by two specialists in nuclear medicine and assessed.
Results:
The lung volume calculated from lung CT was 3749 ± 788 ml. The lung volume calculated from lung perfusion SPECT without using the breathing synchronization software was 3091 ± 610 ml. There was a significant difference between the lung volume calculated from CT and SPECT without using the breathing synchronization software (P < 0.01). The lung volume calculated from lung perfusion SPECT using the breathing synchronization software was 3435 ± 686 ml, and there was no significant difference between the lung volume calculated from CT and SPECT using the breathing synchronization software. The visual score improved with the use of breathing synchronization software (without software; 1.9 ± 0.6 vs. with software; 3.4 ± 0.7, P < 0.001).
Conclusion:
This study demonstrated that the breathing synchronization software could improve conformity between lung perfusion SPECT and lung CT.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...

